The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
What Tidal Volumes Should Be Used in Patients without Acute Lung Injury?
Open accessAbstract
Mechanical ventilation practice has changed over the past few decades, with tidal volumes (VT) decreasing significantly, especially in patients with acute lung injury (ALI). Patients without acute lung injury are still ventilated with large--and perhaps too large--VT. Studies of ventilator-associated lung injury in subjects without ALI demonstrate inconsistent results. Retrospective clinical studies, however, suggest that the use of large VT favors the development of lung injury in these patients. Side effects associated with the use of lower VT in patients with ALI seem to be minimal. Assuming that this will be the case in patients without ALI/acute respiratory distress syndrome too, the authors suggest that the use of lower VT should be considered in all mechanically ventilated patients whether they have ALI or not. Prospective studies should be performed to evaluate optimal ventilator management strategies for patients without ALI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Ranieri, V. M., Suter, P. M., Tortorella, C., De Tullio, R., Dayer, J. M., Brienza, A., Bruno, F., & Slutsky, A. S. (1999) · JAMA · doi:10.1001/jama.282.1.54 · Cited by 1,908
Self-citationEsteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
Dreyfuss, D., Soler, P., Basset, G., & Saumon, G. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.5.1159 · Cited by 1,717
Reference spirometric values using techniques and equipment that meet ATS recommendations.
Terrin, M. (1981) · PubMed · doi:10.1164/arrd.1981.124.6.763c · Cited by 1,374
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Self-citationOptimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure
Suter, P. M., Fairley, H. B., & Isenberg, M. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197502062920604 · Cited by 1,295
Cited by
A trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
Self-citationJaber, S., Jung, B., Corne, P., Sebbane, M., Muller, L., Chanques, G., Verzilli, D., Jonquet, O., Eledjam, J.-J., & Lefrant, J.-Y. (2010) · Intensive Care Medicine · doi:10.1007/s00134-009-1717-8 · Cited by 508
Lung Stress and Strain during Mechanical Ventilation: Any Safe Threshold?
Protti, A., Cressoni, M., Santini, A., Langer, T., Mietto, C., Febres, D., Chierichetti, M., Coppola, S., Conte, G., Gatti, S., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201010-1757oc · Cited by 346
Dupanovic, M. (2015) · Encyclopedia of Trauma Care · doi:10.1007/978-3-642-29613-0_456
Metadata
- Authors
- Schultz, M. J., Haitsma, J. J., Slutsky, A. S., Gajic, O., & Warltier, D. C.
- Venue
- Anesthesiology
- Published
- 2007-06-01
- Volume
- 106
- Issue
- 6
- Pages
- 1226-1231
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1986525739
- Cited by
- 296
- References
- 37
- FWCI
- 18.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What Tidal Volumes Should Be Used in Patients without Acute Lung Injury? https://app.cochat.ai/papers/10.1097/01.anes.0000267607.25011.e8
- The paper
- Schultz, M. J., Haitsma, J. J., Slutsky, A. S., Gajic, O., & Warltier, D. C. (2007). What Tidal Volumes Should Be Used in Patients without Acute Lung Injury? Anesthesiology. https://doi.org/10.1097/01.anes.0000267607.25011.e8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.