OBJECTIVE: Manual vacuum aspiration is an alternative to electric suction curettage for first-trimester elective abortion. Although many studies have demonstrated that manual vacuum aspiration is safer than sharp curettage for abortion, only a few studies have directly compared it with electric suction curettage. These studies proved the methods to be equally effective and acceptable but were too small to adequately compare safety. We compared immediate complication rates for abortions performed by manual and electric vacuum aspiration. METHODS: We conducted a retrospective cohort analysis of all women undergoing elective abortion at up to 10 weeks' gestation at San Francisco General Hospital over a 3.5-year period. A total of 1726 procedures were included: 1002 manual and 724 electric vacuum aspirations. Clinical data were collected from medical records. Rates of uterine reaspiration and other immediate complications occurring at our institution were compared. RESULTS: We found no difference in the rate of uterine reaspiration after abortions performed with the manual or electric suction device (2.2% versus 1.7%, respectively, P =.43). We had 80% statistical power to detect a 2% difference in uterine reaspiration rates with an microa error of.05. Overall major complication rates were 2.5% with manual and 2.1% with electric suction curettage, P =.56. Multivariable regression analyses controlling for potential confounders showed no difference in uterine reaspiration rates (electric odds ratio [OR] = 0.71, 95% confidence interval [CI] 0.32, 1.6) or overall complications (electric OR = 0.81, 95% CI 0.40, 1.7). CONCLUSION: Manual vacuum aspiration is as safe as electric suction curettage for abortions at up to 10 weeks' gestation. Expanded use in an office setting might increase abortion access.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACOG Practice Bulletin No. 200: Early Pregnancy Loss
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002899 · Cited by 483
Manual versus electric vacuum aspiration for first‐trimester abortion: a systematic review
Wen, J., Cai, Q., Deng, F., & Li, Y. (2008) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2007.01572.x · Cited by 96
No. 360-induced abortion: surgical abortion and second-trimester medical methods
Costescu, D., & Guilbert, É. (2018) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2017.12.010 · Cited by 50
“Both MVA and EVA are safe and effective.(3,130,147,151)”
BackgroundCervical dilation before first-trimester surgical abortion (< 14 weeks' gestation)
Allen, R. H., & Goldberg, A. B. (2016) · Contraception · doi:10.1016/j.contraception.2015.12.001 · Cited by 50
Self-citation
Metadata
- Authors
- Goldberg, A. B., Dean, G., Kang, M.-S., Youssof, S., & Darney, P. D.
- Venue
- Obstetrics & Gynecology
- Published
- 2004-01
- Volume
- 103
- Issue
- 1
- Pages
- 101-107
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2047811525
- Cited by
- 92
- References
- 0
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Manual Versus Electric Vacuum Aspiration for Early First-Trimester Abortion: A Controlled Study of Complication Rates. https://app.cochat.ai/papers/10.1097/01.aog.0000109147.23082.25
- The paper
- Goldberg, A. B., Dean, G., Kang, M.-S., Youssof, S., & Darney, P. D. (2004). Manual Versus Electric Vacuum Aspiration for Early First-Trimester Abortion: A Controlled Study of Complication Rates. Obstetrics & Gynecology. https://doi.org/10.1097/01.aog.0000109147.23082.25
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.