Accuracy of Transvaginal Ultrasonography in Diabetic or Obese Women With Postmenopausal Bleeding
The DOI matches its Crossref record.
Abstract
OBJECTIVE: We sought to assess the accuracy of endometrial thickness measurement in the diagnosis of endometrial cancer in patients with obesity, diabetes, and hypertension and to evaluate whether patient characteristics influence endometrial thickness irrespective of the final diagnosis. METHODS: This was a prospective study of women not using hormone replacement therapy who presented with postmenopausal bleeding at 8 hospitals in The Netherlands. All women underwent transvaginal ultrasonography and, in the event that the endometrial thickness (double layer) was more than 4 mm, subsequent endometrial sampling. The performance of endometrial thickness measurement in the diagnosis of atypical hyperplasia and endometrial cancer was evaluated in subgroups of patients with diabetes, hypertension, and obesity by using receiver operating characteristic analysis. RESULTS: Overall, we included 594 consecutive women, of whom 62 (10%) had endometrial carcinoma and 6 (1%) had atypical hyperplasia. In these women, transvaginal ultrasonography had an area under the receiver operating characteristic curve of 0.87 (standard error [SE] 0.03). In the absence of (pre)malignancy, women with diabetes or obesity were found to have thicker endometria than women without these risk factors, whereas in women with a (pre)malignancy, this difference was not present. The area under the receiver operating characteristic curve decreased to 0.74 (SE 0.05) and 0.75 (SE 0.07) in diabetic women and obese women, respectively. The presence or absence of hypertension had no impact on the accuracy of transvaginal ultrasonography. CONCLUSION: In view of the decreased diagnostic accuracy in diabetic women and obese women, the clinical value of transvaginal endometrial thickness measurement in these women is questionable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Timmermans, A., Opmeer, B. C., Khan, K. S., Bachmann, L. M., Epstein, E., Clark, T. J., Gupta, J. K., Bakour, S. H., van den Bosch, T., van Doorn, H. C., et al. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181e3e7e8 · Cited by 312
Self-citationDiagnostic strategies for postmenopausal bleeding.
Breijer, M. C., Timmermans, A., van Doorn, H. C., Mol, B. W. J., & Opmeer, B. C. (2010) · Obstetrics and Gynecology International · doi:10.1155/2010/850812 · Cited by 82
Self-citationPrediction models in women with postmenopausal bleeding: a systematic review.
van Hanegem, N., Breijer, M. C., Opmeer, B. C., Mol, B. W., & Timmermans, A. (2012) · Women's Health · doi:10.2217/whe.12.10 · Cited by 12
“In women with PMB there is considerable variability in endometrial thickness and the likelihood of endometrial carcinoma [10].”
BackgroundSelf-citation
Metadata
- Authors
- van Doorn, L. C., Dijkhuizen, F. P. H. L. J., Kruitwagen, R. F. M. P., Heintz, A. P. M., Kooi, G. S., & Mol, B. W. J.
- Venue
- Obstetrics & Gynecology
- Published
- 2004-09
- Volume
- 104
- Issue
- 3
- Pages
- 571-578
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1988204881
- Cited by
- 45
- References
- 0
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Transvaginal Ultrasonography in Diabetic or Obese Women With Postmenopausal Bleeding. https://app.cochat.ai/papers/10.1097/01.aog.0000136080.55874.7f
- The paper
- van Doorn, L. C., Dijkhuizen, F. P. H. L. J., Kruitwagen, R. F. M. P., Heintz, A. P. M., Kooi, G. S., & Mol, B. W. J. (2004). Accuracy of Transvaginal Ultrasonography in Diabetic or Obese Women With Postmenopausal Bleeding. Obstetrics & Gynecology. https://doi.org/10.1097/01.aog.0000136080.55874.7f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.