The DOI matches its Crossref record.
Chorionic Villus Sampling Compared With Amniocentesis and the Difference in the Rate of Pregnancy Loss
Abstract
OBJECTIVE: To compare loss rates following amniocentesis and chorionic villus sampling (CVS) over time. METHODS: A retrospective cohort study of all amniocentesis and CVS procedures resulting in a normal karyotype from 1983-2003 at a single prenatal diagnostic referral center was conducted. Pregnancy loss rates for amniocentesis, CVS, and nonintervention groups (ie, those who had nuchal translucency screening or counseling, but no procedure) were compared using the chi 2 test. Year of procedure, maternal age, parity, race or ethnicity, and gestational age at procedure were controlled for in multivariable logistic regression models. RESULTS: There were 9,886 CVS and 30,893 amniocentesis procedures performed during the study period that resulted in a normal karyotype. The overall loss rates were 3.12% for CVS and 0.83% for amniocentesis (P < .001). When examined by 5-year intervals, there was a statistically significant decrease in the CVS loss rate (P < .001) and a nonsignificant lesser decrease in the loss rate for amniocentesis over time. Although the pregnancy loss rate from CVS over the entire study period was higher than from amniocentesis (adjusted odds ratio 4.23, 95% confidence interval 2.29-7.81), in the most recent time period, 1998 to 2003, there was no difference between the two procedures (adjusted odds ratio 1.03, 95% confidence interval 0.23-4.52). CONCLUSION: The loss rates for both amniocentesis and CVS at our institution have decreased over time. Because the decrease in loss rate for CVS has been greater, there is no longer a statistically significant difference between the two. These results are informative in both patient counseling and establishing widespread prenatal diagnostic and screening programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
Procedure-Related Complications of Amniocentesis and Chorionic Villous Sampling: A Systematic Review
Mujezinovic, F., & Alfirevic, Z. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000278820.54029.e3 · Cited by 446
Sparks, A. B., Struble, C. A., Wang, E. T., Song, K., & Oliphant, A. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2012.01.030 · Cited by 395
Practice Bulletin No. 162: Prenatal Diagnostic Testing for Genetic Disorders
(2016) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001405 · Cited by 309
Roubelakis, M. G., Pappa, K. I., Bitsika, V., Zagoura, D., Vlahou, A., Papadaki, H. A., Antsaklis, A., & Anagnou, N. P. (2007) · Stem Cells and Development · doi:10.1089/scd.2007.0036 · Cited by 283
Metadata
- Authors
- Caughey, A. B., Hopkins, L. M., & Norton, M. E.
- Venue
- Obstetrics & Gynecology
- Published
- 2006-09
- Volume
- 108
- Issue
- 3, Part 1
- Pages
- 612-616
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1990795167
- Cited by
- 235
- References
- 0
- FWCI
- 13.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chorionic Villus Sampling Compared With Amniocentesis and the Difference in the Rate of Pregnancy Loss. https://app.cochat.ai/papers/10.1097/01.aog.0000232512.46869.fc
- The paper
- Caughey, A. B., Hopkins, L. M., & Norton, M. E. (2006). Chorionic Villus Sampling Compared With Amniocentesis and the Difference in the Rate of Pregnancy Loss. Obstetrics & Gynecology. https://doi.org/10.1097/01.aog.0000232512.46869.fc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.