Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 515

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta

Warshak, Carri R., Eskander, Ramez, Hull, Andrew D., Scioscia, Angela L., Mattrey, Robert F., Benirschke, Kurt, Resnik, Robert·2006·Obstetrics & Gynecology

Abstract

BACKGROUND: The incidence of placenta accreta has increased dramatically over the last three decades, in concert with the increase in the cesarean delivery rate. Optimal management requires accurate prenatal diagnosis. The purpose of this study was to determine the precision and reliability of ultrasonography and magnetic resonance imaging (MRI) in diagnosing placenta accreta. METHODS: A historical cohort study was performed with information gathered from our obstetric, radiologic, and pathology databases. Records from January 2000 to June 2005 were reviewed to identify patients with a diagnosis of placenta previa, low-lying placenta with a prior cesarean delivery, or history of a myomectomy to determine the accuracy of pelvic ultrasonography in the diagnosis of placenta accreta. The records of those considered to be suspicious for placenta accreta and subsequently referred for additional confirmation by MRI were also analyzed. The sonographic and MRI diagnoses were compared with the final pathologic or operative findings or with both. RESULTS: Of the 453 women with placenta previa, previous cesarean delivery and low-lying anterior placenta, or previous myomectomy, 39 had placenta accreta confirmed by pathological examination. Ultrasonography accurately predicted placenta accreta in 30 of 39 of women and correctly ruled out placenta accreta in 398 of 414 without placenta accreta (sensitivity 0.77, specificity 0.96). Forty-two women underwent MRI evaluation because of findings suspicious or inconclusive of placenta accreta by ultrasonography. Magnetic resonance imaging accurately predicted placenta accreta in 23 of 26 cases with placenta accreta and correctly ruled out placenta accreta in 14 of 14 (sensitivity 0.88, specificity 1.0). CONCLUSION: A two-stage protocol for evaluating women at high risk for placenta accreta, which uses ultrasonography first, and then MRI for cases with inconclusive ultrasound features, will optimize diagnostic accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.aog.0000233155.62906.6d

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 515

Metadata

Authors
Warshak, C. R., Eskander, R., Hull, A. D., Scioscia, A. L., Mattrey, R. F., Benirschke, K., & Resnik, R.
Venue
Obstetrics & Gynecology
Published
2006-09
Volume
108
Issue
3, Part 1
Pages
573-581
ISSN
0029-7844 (ISSN-L)
OpenAlex
W1968848926
Cited by
515
References
14
FWCI
16.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta. https://app.cochat.ai/papers/10.1097/01.aog.0000233155.62906.6d
The paper
Warshak, C. R., Eskander, R., Hull, A. D., Scioscia, A. L., Mattrey, R. F., Benirschke, K., & Resnik, R. (2006). Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta. Obstetrics & Gynecology. https://doi.org/10.1097/01.aog.0000233155.62906.6d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.