A breakthrough in tumor localization: combining tactile sensing and ultrasound to improve tumor localization in robotics-assisted minimally invasive surgery

Naidu, Anish S., Naish, Michael D., Patel, Rajni V.·2017·IEEE Robotics & Automation Magazine

Abstract

Robotics-assisted minimally invasive surgery (RAMIS) helps surgeons to avoid manually palpating organs to locate subsurface tumors. One solution has been to use ultrasound, but it is not always reliable. Tactile sensing, however, has the potential to augment ultrasound to improve tumor localization, but there are no existing RAMIS instruments that employ both modalities.

Integrity signals

Registry

Crossref · 10.1109/mra.2017.2680544

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The artificial tactile sensing system can detect mass calcifications inside breast tissue based on palpation and comparison with reference data, and determine significant abnormalities.

    “The tactile sensory system can detect mass calcifications inside the breast tissue based on palpation of different points of the tissue and comparing with different reference data, and subsequently determine whether there are any significant abnormalities in the breast tissue.”
  • Artificial tactile sensing has been used for breast cancer screening as a replacement for clinical breast examination to complement medical imaging such as x-ray mammography and MRI.

    “An example where artificial tactile sensing has been used includes screening of breast cancer, as a replacement for clinical breast examination to complement medical imaging techniques such as x-ray mammography and MRI.”

Cites

Flagged first, then by citations

1 of the 20 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Naidu, A. S., Naish, M. D., & Patel, R. V.
Affiliations
  • Lawson Health Research Institute (CA)
  • Western University (CA)
Venue
IEEE Robotics & Automation Magazine
Published
2017-06
Volume
24
Issue
2
Pages
54-62
ISSN
1070-9932 (ISSN-L)
OpenAlex
W2612628788
Cited by
27
References
20
Citations by year
2025: 5 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 4 · 2017: 1
FWCI
1.36
Type
journal article
Language
en
Open access
closed
Locations
IEEE Robotics & Automation Magazine (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
  • Health Sciences › Medicine › Surgery › Surgical Simulation and Training
Keywords
tumor localization, tactile sensing, ultrasound, multimodal sensing, surgical instruments

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review