Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Successful total knee arthroplasty is dependent on the correct alignment of implanted prostheses. Major clinical problems can be related to poor femoral component positioning, including sagittal plane and rotational malalignment. A prospective randomized study was designed to test whether an optical navigation system for total knee arthroplasty achieved greater implantation precision than a nonnavigated technique. The primary variable was rotation of the femoral component in the transverse plane, measured from postoperative radiographs and computed tomography images. Sixty-four patients were included in the study. All patients received the Duracon total knee prosthesis. The patients were randomly divided into two groups: Group C patients had conventional total knee arthroplasty without navigation; Group N patients had total knee arthroplasty using a computer-assisted knee navigation system. Analysis showed that patients in Group N had significantly better rotational alignment and flexion angle of the femoral component than patients in Group C. In addition, superior postoperative alignment of the mechanical axis, posterior tibial slope, and rotational alignment was achieved for patients in Group N. The use of a navigation system provides improved alignment accuracy, and can help to avoid femoral malrotation and errors in axial alignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System
Ewald, F. C. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198911000-00003 · Cited by 1,971
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Berger, R. A., Rubash, H. E., Seel, M. J., THOMPSON, W. H., & Crossett, L. S. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199301000-00008 · Cited by 901
The Axes of Rotation of the Knee
HOLLISTER, A. M., JATANA, S., SINGH, A. K., SULLIVAN, W. W., & LUPICHUK, A. G. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199305000-00033 · Cited by 502
ANOUCHI, Y. S., WHITESIDE, L. A., KAISER, A. D., & MILLIANO, M. T. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199302000-00027 · Cited by 382
Anatomy of the epicondyles of the distal femur
Griffin, F. M., Math, K., Scuderi, G. R., Insall, J. N., & Poilvache, P. L. (2000) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(00)90739-3 · Cited by 253
The Effect of Femoral Component Position on Patellar Tracking After Total Knee Arthroplasty
RHOADS, D. D., NOBLE, P. C., REUBEN, J. D., MAHONEY, O. M., & TULLOS, H. S. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199011000-00009 · Cited by 238
Prediction of total knee motion using a three-dimensional computer-graphics model
Garg, A., & Walker, P. S. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90368-d · Cited by 175
Bone Anatomy and Rotational Alignment in Total Knee Arthroplasty
Uehara, K., Kadoya, Y., Kobayashi, A., Ohashi, H., & Yamano, Y. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200209000-00018 · Cited by 150
Effect of Rotation on the Axial Alignment of the Femur
Jiang, C., & Insall, J. N. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198911000-00009 · Cited by 97
Stähelin, T., Kessler, O., Pfirrmann, C. W. A., Jacob, H. A. C., & Romero, J. (2003) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(03)00060-3 · Cited by 50
Self-citation
Cited by
Choong, P. F., Dowsey, M. M., & Stoney, J. D. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.02.018 · Cited by 447
Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00002 · Cited by 429
Navigated Total Knee Replacement: A Meta-Analysis
Bauwens, K., Matthes, G., Wich, M., Gebhard, F., Hanson, B., Ekkernkamp, A., & Stengel, D. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00005 · Cited by 399
Cobb, J., Henckel, J., Gomes, P., Harris, S., Jakopec, M., Rodriguez, F., Barrett, A., & Davies, B. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b2.17220 · Cited by 333
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Metadata
- Authors
- St??ckl, B., Nogler, M., Rosiek, R., Fischer, M., Krismer, M., & Kessler, O.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2004-09
- Volume
- 426
- Issue
- 426
- Pages
- 180-186
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2020648651
- Cited by
- 286
- References
- 11
- FWCI
- 21.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.