Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 429

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

A Prospective, Randomized Study of Computer-Assisted and Conventional Total Knee Arthroplasty: Three-Dimensional Evaluation of Implant Alignment and Rotation

Matziolis, Georg, Krocker, Doerte, Weiss, Ulrike, Tohtz, Stephan, Perka, Carsten·2007·The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: Despite the use of modern instruments in total knee arthroplasty, component malalignment remains a problem. Whether a computer-assisted implantation technique can improve the accuracy of the spatial positioning of an implant is a matter of debate. The objective of this study was to determine whether computer-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. METHODS: The spatial positioning of the implant in sixty total knee arthroplasties (thirty-two imageless computer-assisted and twenty-eight conventional implantations) was determined three-dimensionally with use of computed tomographic measurement, which allowed derotation and full extension of the knee in order to avoid projection-related imaging errors. RESULTS: The overall mechanical axis showed a range of between 4.8 degrees of valgus and 6.6 degrees of varus alignment in the frontal plane for conventionally implanted arthroplasty components compared with a significantly smaller range of between 2.9 degrees of valgus and 3.1 degrees of varus alignment for computer-assisted implantations (p = 0.004). In relation to the tibial implant, the mean deviation (and standard deviation) from the mechanical axis was 2.0 degrees +/- 1.7 degrees for the conventional surgical method and 1.4 degrees +/- 0.9 degrees for the navigated implantation. The rotational deviation from the referenced axis of the femoral component was between 3.3 degrees of internal rotation and 5.0 degrees of external rotation for the conventional implantation method, with a mean deviation of 0.1 degrees +/- 2.2 degrees. Femoral components implanted with computer assistance showed a deviation of between 4.7 degrees of internal rotation and 2.2 degrees of external rotation, with a mean deviation of 0.3 degrees +/- 1.4 degrees. CONCLUSIONS: In this study, with our technique of filtering out projection-related imaging errors, computer-assisted implantation of total knee replacements improved the frontal and sagittal alignment of the femoral component but not of the tibial component. We found that the rotational alignment of the component was not improved through navigation by solely referencing to the epicondylar axis for the femur and the tuberosity for the tibia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-200702000-00002

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 429

Metadata

Authors
Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2007-02
Volume
89
Issue
2
Pages
236-243
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2007653757
Cited by
429
References
12
FWCI
28.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Prospective, Randomized Study of Computer-Assisted and Conventional Total Knee Arthroplasty: Three-Dimensional Evaluation of Implant Alignment and Rotation. https://app.cochat.ai/papers/10.2106/00004623-200702000-00002
The paper
Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007). A Prospective, Randomized Study of Computer-Assisted and Conventional Total Knee Arthroplasty: Three-Dimensional Evaluation of Implant Alignment and Rotation. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200702000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.