Alternative Materials to Acrylic Bone Cement for Delivery of Depot Antibiotics in Orthopaedic Infections
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Acrylic bone cement has considerable laboratory and clinical data validating it as a delivery material for depot administration of antibiotics. However, an alternate material that does not require a secondary procedure for removal is desired. Many biodegradable materials have been evaluated as alternatives including protein-based materials (collagen, fibrin, thrombin, clotted blood), bone-graft, bone-graft substitutes and extenders (hydroxyapatite, beta-tricalcium phosphate, calcium sulfate, bioglass), and synthetic polymers (polyhanhydride, polylactide, polyglycolide, polyhydroxybutyrate-co-hydroxyvalerate, polyhydroxyalkanoate). Various forms and combinations of these materials have been investigated worldwide, characterizing their elution properties and performance in treating osteomyelitis in animal models. Many of these have had limited clinical evaluation. Outside the United States, some of these materials are used clinically. In the United States, none have been approved. None are commercially available for clinical use. Morselized cancellous bone and calcium sulfate are the two materials that have been used clinically in the United States on a physician-prescribed, hand-mixed, basis. Considering the limited clinical data that currently are available, the use of these materials still is experimental. Clinical application should be cautious, limiting the total antibiotic load. Until definitive data are available, a prudent dose would be no higher than one that would have acceptable toxicity risk if administered intravenously over 24 hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Local antibiotic therapy for severe open fractures. A review of 1085 consecutive cases
Ostermann, P., Seligson, D., & Henry, S. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b1.7822405 · Cited by 327 · cited 1×
“Polymethylmethacrylate (PMMA) is the standard material used as the delivery vehicle for depot antibiotics in orthopaedic surgery.(14,20,37) However, there are concerns about the use of PMMA that have led to the search for alternate materials to be used as the delivery vehicle.”
BackgroundCarrier Systems for the Local Delivery of Antibiotics in Bone Infections
Kanellakopoulou, K., & Giamarellos-Bourboulis, E. J. (2000) · Drugs · doi:10.2165/00003495-200059060-00003 · Cited by 320
Biomaterial-associated infection of gentamicin-loaded PMMA beads in orthopaedic revision surgery
Neut, D. (2001) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/47.6.885 · Cited by 296 · cited 1×
“Polymethylmethacrylate is surface friendly to biofilmforming bacteria.(4,18,34,38,43) This presents a potential risk of retained PMMA acting as a surface for the reestablishment of the original bacteria or for the initiation of an infection by new bacteria.”
BackgroundThe influence of skeletal implants on incidence of infection. Experiments in a canine model.
Petty, W., Spanier, S., Shuster, J. J., & Silverthorne, C. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00015 · Cited by 283
The Treatment of Chronic Osteomyelitis with a Biodegradable Antibiotic-Impregnated Implant
Gitelis, S., & Brebach, G. T. (2002) · Journal of Orthopaedic Surgery · doi:10.1177/230949900201000110 · Cited by 225
Use of Antibiotic-Impregnated Cement in Total Joint Arthroplasty
Joseph, T. N., Chen, A. L., & Di Cesare, P. E. (2003) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200301000-00006 · Cited by 224 · cited 1×
“Polymethylmethacrylate (PMMA) is the standard material used as the delivery vehicle for depot antibiotics in orthopaedic surgery.(14,20,37) However, there are concerns about the use of PMMA that have led to the search for alternate materials to be used as the delivery vehicle.”
BackgroundNeut, D., van de Belt, H., van Horn, J. R., van der Mei, H. C., & Busscher, H. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00614-2 · Cited by 196 · cited 2×
“This concern has not been realized in clinical practice,(9,17) although bacteria may be present without overt clinical manifestation.(35) As with all delivery vehicle materials, the antibiotic levels in the wound decrease over time.”
BackgroundKLEMM, K. W. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199310000-00011 · Cited by 194 · cited 1×
“Polymethylmethacrylate (PMMA) is the standard material used as the delivery vehicle for depot antibiotics in orthopaedic surgery.(14,20,37) However, there are concerns about the use of PMMA that have led to the search for alternate materials to be used as the delivery vehicle.”
BackgroundBelt, H. V. D., Neut, D., Schenk, W., Horn, J. R. V., Mei, H. C. V. D., & Busscher, H. J. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317362280 · Cited by 168 · cited 1×
“Microfibrillar Type 1 collagen (bovine or porcine), lyophilized collagen sponge, gelatin, human fibrinogen and thrombin, albumin, and autologous blood clot have all been used clinically, both individually and in combination.(1,7,10,13,21,32,44) These materials function as delivery vehicles by providing a physical scaf…”
MethodNelson, C. L., McLaren, S. G., Skinner, R. A., Smeltzer, M. S., Thomas, J. R., & Olsen, K. M. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00133-4 · Cited by 160 · cited 2×
“proximately 20% of contained antibiotic is released during the first 24 hours in a rabbit model.(33) Clinical data are”
Background
Cited by
ANTIBIOTIC-LOADED BONE CEMENT FOR INFECTION PROPHYLAXIS IN TOTAL JOINT REPLACEMENT
JIRANEK, W. A., HANSSEN, A. D., & GREENWALD, A. S. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200611000-00024 · Cited by 411
Jagur‐Grodzinski, J. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.729 · Cited by 394
Osteomyelitis: Recent advances in pathophysiology and therapeutic strategies
Birt, M. C., Anderson, D. W., Bruce Toby, E., & Wang, J. (2017) · Journal of Orthopaedics · doi:10.1016/j.jor.2016.10.004 · Cited by 238
“Calcium sulfate (CaSO4) and calcium phosphate biomaterials such as beta-tricalcium phosphate (b-TCP, Ca3(PO4)2) and hydroxyapatite (HA, Ca10(PO4)6(OH)2) have been used as biodegradable ceramic carrier materials for treatment of osteomyelitis in animal models and clinical studies.(49,69,70) Silver has been used as a co…”
BackgroundLocal Antibiotic Delivery Vehicles in the Treatment of Musculoskeletal Infection
Hanssen, A. D. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000175713.30506.77 · Cited by 234
Stem cell-biomaterial interactions for regenerative medicine
Martino, S., D'Angelo, F., Armentano, I., Kenny, J. M., & Orlacchio, A. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.015 · Cited by 218
“TCP has been formulated into several formats, but the disadvantage of the unpredictable rate of bioresorption is still unresolved (McLaren, 2004; Schwartz et al., 2008).”
BackgroundAntimicrobial delivery systems for local infection prophylaxis in orthopedic- and trauma surgery
ter Boo, G.-J. A., Grijpma, D. W., Moriarty, T. F., Richards, R. G., & Eglin, D. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.020 · Cited by 209
Local Antibiotic Therapy in Osteomyelitis
Gogia, J., Meehan, J., Di Cesare, P., & Jamali, A. (2009) · Seminars in Plastic Surgery · doi:10.1055/s-0029-1214162 · Cited by 207
Li, B., Brown, K. V., Wenke, J. C., & Guelcher, S. A. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.04.002 · Cited by 198
Metsemakers, W.-J., Fragomen, A. T., Moriarty, T. F., Morgenstern, M., Egol, K. A., Zalavras, C., Obremskey, W. T., Raschke, M., McNally, M. A., & on behalf of the Fracture-Related Infection (FRI) consensus group (2020) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000001615 · Cited by 193
Biodegradable vs non-biodegradable antibiotic delivery devices in the treatment of osteomyelitis
Kluin, O. S., van der Mei, H. C., Busscher, H. J., & Neut, D. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.751371 · Cited by 171
“Calcium sulphate carriers potentially aid in bone repair, but their actual capability in doing so is disputed [77,63].”
BackgroundHake, M. E., Young, H., Hak, D. J., Stahel, P. F., Hammerberg, E. M., & Mauffrey, C. (2015) · Injury · doi:10.1016/j.injury.2015.05.008 · Cited by 169
“Bone grafts and bone graft substitutes have been used successfully in conjunction with local antibiotics [15].”
Background
Metadata
- Authors
- McLaren, A. C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2004-10
- Volume
- 427
- Issue
- 427
- Pages
- 101-106
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1973175988
- Cited by
- 171
- References
- 23
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.