Wear, Debris, and Biologic Activity of Cross-linked Polyethylene in the Knee: Benefits and Potential Concerns
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Cross-linked polyethylene currently is being introduced in knee prostheses. The wear rates, wear debris, and biologic reactivity of non cross-linked, moderately cross-linked, and highly cross-linked polyethylene have been compared in multidirectional wear tests and knee simulators. Multidirectional pin-on-plate wear studies of noncross-linked, moderately cross-linked (5 Mrad), and highly cross-linked (10 Mrad) polyethylene showed a 75% reduction in wear with the highly cross-linked material under kinematics found in the hip, but only a 33% reduction under wear in kinematics representative of the knee. In knee simulator studies, with the fixed-bearing press-fit, condylar Sigma cruciate-retaining knee under high kinematic input conditions, the wear of 5 Mrad moderately cross-linked polyethylene was 13 +/- 4 mm per 1 million cycles, which was lower (p < 0.05) than the wear of clinically used, gamma vacuum foil GUR 1020 polyethylene (23 +/- 6 mm/1 million cycles). For the low-contact stress mobile-bearing knee, the wear of moderately cross-linked polyethylene was 2 +/- 1 mm per 1 million cycles, which was lower (p < 0.05) than GVF GUR 1020 polyethylene (5 +/- 2 mm/1 million cycles). The wear debris isolated from the fixed-bearing knees showed the moderately cross-linked material had a larger percentage volume of particles smaller than 1 mum in size, compared with GVF GUR 1020 polyethylene. Direct cell culture studies of wear debris generated in sterile wear simulators using multidirectional motion showed a increase (p < 0.05) in tumor necrosis factor-alpha levels and reactivity for GUR 1050 cross-linked polyethylene debris compared with an equivalent volume of noncross-linked GUR 1050 polyethylene. The use of cross-linked polyethylene in the knee reduces the volumetric wear rate. However, the clinical significance of reduced fracture toughness, elevated wear in abrasive conditions, and the elevated tumor necrosis factor-alpha release from smaller more reactive particles warrant further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Properties of crosslinked ultra-high-molecular-weight polyethylene
Lewis, G. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00195-2 · Cited by 288
Matthews, J. B., Besong, A. A., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J., & Ingham, E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<296::aid-jbm8>3.0.co;2-9 · Cited by 212 · cited 1×
“These observations are particularly important, as it has been shown separately in in vitro cell culture systems that a unit volume of PE wear debris below 1 m in size is six times more reactive than a unit volume of wear debris above 1 m in size.(6,11) Clinical studies of highly cross-linked PE in the hip are progress…”
BackgroundSelf-citationEndo, M., Tipper, J. L., Barton, D. C., Stone, M. H., Ingham, E., & Fisher, J. (2002) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411021536333 · Cited by 190 · cited 12×
“This was compared with moderately cross-linked GUR 1050 (5 Mrad) PE.”
BackgroundResultSelf-citationIngram, J. H., Stone, M., Fisher, J., & Ingham, E. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.054 · Cited by 181
Self-citationTipper, J. L., Firkins, P., Besong, A. A., Barbour, P. S. M., Nevelos, J., Stone, M. H., Ingham, E., & Fisher, J. (2001) · Wear · doi:10.1016/s0043-1648(01)00653-6 · Cited by 127 · cited 1×
“particle numbers and volumes were determined using scanning electron microscopy.(15) In this study, a field emission gun scan-”
MethodSelf-citationHowling, G. I., Barnett, P. I., Tipper, J. L., Stone, M. H., Fisher, J., & Ingham, E. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1036 · Cited by 76 · cited 3×
“The low percentage volume of debris below 1 m in size in the conventional material in the knee is consistent with a recent study.(7) The volume distributions were used to predict specific biologic activity(5) of the wear debris.”
BackgroundResultSelf-citationDʼLima, D. D., Hermida, J. C., Chen, P., & Colwell, C. W. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00240-1 · Cited by 62 · cited 3×
“Joint simulators allow rigorous preclinical evaluation of wear of artificial joints in a controlled environment and independent assessment of variables such as materials, design, and kinematics.(1,2) More recently, wear debris has been analyzed(3,4) and the release of osteolytic cytokines from wear debris cultured wit…”
BackgroundResult
Cited by
Osteolysis around total knee arthroplasty: A review of pathogenetic mechanisms
Gallo, J., Goodman, S. B., Konttinen, Y. T., Wimmer, M. A., & Holinka, M. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.05.005 · Cited by 353
UHMWPE for arthroplasty: past or future?
Brach del Prever, E. M., Bistolfi, A., Bracco, P., & Costa, L. (2009) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-008-0038-y · Cited by 188
“Crosslinking would generate a larger percentage of small particles [39, 40], which would lead to a higher release of tumor necrosis factor-alpha and therefore to a higher reactivity [ 41 ].”
BackgroundPablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
Metadata
- Authors
- Fisher, J., McEwen, H. M. J., Tipper, J. L., Galvin, A. L., Ingram, J., Kamali, A., Stone, M. H., & Ingham, E.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2004-11
- Volume
- 428
- Issue
- 428
- Pages
- 114-119
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2023560397
- Cited by
- 185
- References
- 7
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.