Alumina Ceramic Bearings for Total Hip Arthroplasty: Five-year Results of a Prospective Randomized Study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Three hundred twenty-eight ceramic bearings were implanted by six surgeons in 316 patients as a part of a prospective randomized US Investigational Device Exemption study comparing alumina ceramic bearings with cobalt chrome-on-polyethylene bearings. There was no difference between the control metal-on-polyethylene and the alumina bearing couple patient cohorts regarding demographics or clinical scores through 7 years. Revision for any reason occurred in 2.7% of the patients with alumina bearings and 7.5% of the control patients with polyethylene bearings. Osteolysis was found in 1.4% of the patients with alumina bearings and in 14.0% of the control patients. At an average followup of 5.0 years (range, 1-86 months) no ceramic fractures or ceramic bearing failures have occurred. Results of this study suggest that alumina ceramics perform as well as the metal-on-polyethylene in clinical scores, but the patients with ceramic bearings had fewer revisions and less osteolysis. These results lead us to think that this new alumina ceramic bearing provides a safe option for younger and more active patients. LEVEL OF EVIDENCE: Therapeutic study, Level I-1b (randomized controlled trial, no significant difference, but narrow confidence intervals). See the Guidelines for Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Statistical Aspects of the Analysis of Data From Retrospective Studies of Disease
(1959) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/22.4.719 · Cited by 14,689
HARRIS, W. H. (1969) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196951040-00012 · Cited by 5,640
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_3 · Cited by 5,038
“Modes of Failure” of Cemented Stem-Type Femoral Components: A Radiographic Analysis of Loosening
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_8 · Cited by 3,399
Effect of femoral head size on wear of the polyethylene acetabular component.
Livermore, J., Ilstrup, D., & Morrey, B. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00008 · Cited by 1,024
URBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
A literature review of the association between wear rate and osteolysis in total hip arthroplasty
Dumbleton, J. H., Manley, M. T., & Edidin, A. A. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.33664 · Cited by 710
Self-citationOsteolysis and particle disease in hip replacement: A review
Harris, W. H. (1994) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679408993734 · Cited by 319
Cited by
The operation of the century: total hip replacement
Learmonth, I. D., Young, C., & Rorabeck, C. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60457-7 · Cited by 2,848
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Metadata
- Authors
- D???Antonio, J., Capello, W., Manley, M., Naughton, M., & Sutton, K.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2005-07
- Volume
- &NA;
- Issue
- 436
- Pages
- 164-171
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2091706237
- Cited by
- 168
- References
- 16
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alumina Ceramic Bearings for Total Hip Arthroplasty: Five-year Results of a Prospective Randomized Study. https://app.cochat.ai/papers/10.1097/01.blo.0000162995.50971.39
- The paper
- D???Antonio, J., Capello, W., Manley, M., Naughton, M., & Sutton, K. (2005). Alumina Ceramic Bearings for Total Hip Arthroplasty: Five-year Results of a Prospective Randomized Study. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/01.blo.0000162995.50971.39
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.