Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 234

The DOI matches its Crossref record.

Transmissibility of 15-Hertz to 35-Hertz Vibrations to the Human Hip and Lumbar Spine: Determining the Physiologic Feasibility of Delivering Low-Level Anabolic Mechanical Stimuli to Skeletal Regions at Greatest Risk of Fracture Because of Osteoporosis

Rubin, Clinton, Pope, Malcolm, Chris Fritton, J., Magnusson, Marianne, Hansson, Tommy, McLeod, Kenneth · 2003 · Spine

Abstract

STUDY DESIGN: Experiments were undertaken to determine the degree to which high-frequency (15-35 Hz) ground-based, whole-body vibration are transmitted to the proximal femur and lumbar vertebrae of the standing human. OBJECTIVES: To establish if extremely low-level (<1 g, where 1 g = earth's gravitational field, or 9.8 ms-2) mechanical stimuli can be efficiently delivered to the axial skeleton of a human. SUMMARY OF BACKGROUND DATA: Vibration is most often considered an etiologic factor in low back pain as well as several other musculoskeletal and neurovestibular complications, but recent in vivo experiments in animals indicates that extremely low-level mechanical signals delivered to bone in the frequency range of 15 to 60 Hz can be strongly anabolic. If these mechanical signals can be effectively and noninvasively transmitted in the standing human to reach those sites of the skeleton at greatest risk of osteoporosis, such as the hip and lumbar spine, then vibration could be used as a unique, nonpharmacologic intervention to prevent or reverse bone loss. MATERIALS AND METHODS: Under sterile conditions and local anesthesia, transcutaneous pins were placed in the spinous process of L4 and the greater trochanter of the femur of six volunteers. Each subject stood on an oscillating platform and data were collected from accelerometers fixed to the pins while a vibration platform provided sinusoidal loading at discrete frequencies from 15 to 35 Hz, with accelerations ranging up to 1 g(peak-peak). RESULTS: With the subjects standing erect, transmissibility at the hip exceeded 100% for loading frequencies less than 20 Hz, indicating a resonance. However, at frequencies more than 25 Hz, transmissibility decreased to approximately 80% at the hip and spine. In relaxed stance, transmissibility decreased to 60%. With 20-degree knee flexion, transmissibility was reduced even further to approximately 30%. A phase-lag reached as high as 70 degrees in the hip and spine signals. CONCLUSIONS: These data indicate that extremely low-level, high-frequency mechanical accelerations are readily transmitted into the lower appendicular and axial skeleton of the standing individual. Considering the anabolic potential of exceedingly low-level mechanical signals in this frequency range, this study represents a key step in the development of a biomechanically based treatment for osteoporosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.brs.0000102682.61791.c9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
Rubin, C., Pope, M., Chris Fritton, J., Magnusson, M., Hansson, T., & McLeod, K.
Venue
Spine
Published
2003-12
Volume
28
Issue
23
Pages
2621-2627
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2134028135
Cited by
234
References
0
FWCI
7.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transmissibility of 15-Hertz to 35-Hertz Vibrations to the Human Hip and Lumbar Spine: Determining the Physiologic Feasibility of Delivering Low-Level Anabolic Mechanical Stimuli to Skeletal Regions at Greatest Risk of Fracture Because of Osteoporosis. https://app.cochat.ai/papers/10.1097/01.brs.0000102682.61791.c9
The paper
Rubin, C., Pope, M., Chris Fritton, J., Magnusson, M., Hansson, T., & McLeod, K. (2003). Transmissibility of 15-Hertz to 35-Hertz Vibrations to the Human Hip and Lumbar Spine: Determining the Physiologic Feasibility of Delivering Low-Level Anabolic Mechanical Stimuli to Skeletal Regions at Greatest Risk of Fracture Because of Osteoporosis. Spine. https://doi.org/10.1097/01.brs.0000102682.61791.c9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.