The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Acute Respiratory Distress Syndrome Associated With Pulmonary Cement Embolism Following Percutaneous Vertebroplasty With Polymethylmethacrylate
Abstract
In Brief Study Design. A case of acute respiratory distress syndrome following percutaneous vertebroplasty is described. Objective. To alert clinicians to the potential occurrence of acute respiratory distress syndrome following use of polymethylmethacrylate bone cement. Summary of Background Data. Noncardiogenic pulmonary edema has not been reported following intravertebral injection of polymethylmethacrylate. Methods. A 68-year-old woman underwent percutaneous vertebroplasty for a painful L5 compression fracture under local anesthesia. A contralateral transpedicular approach was made to inject polymethylmethacrylate. Results. On the third postoperative day, she developed arthralgia, myalgia, fever, and frequent coughing. Chest radiography revealed bilateral, multifocal, patchy consolidations, suggestive of acute respiratory distress syndrome, and a 5-cm-long tubular radiopacity in the right pulmonary artery. She died 20 days after the vertebroplasty. Conclusion. This case illustrates that clinicians must be aware of the potential occurrence of acute respiratory distress syndrome in patients who received percutaneous vertebroplasty. Among the cardiovascular and respiratory complications associated with the use of polymethylmethacrylate cement in arthroplasty, a noncardiogenic pulmonary edema has not been documented. We report on 1 patient with progressive hypoxemia and diffuse pulmonary infiltrates following intravertebral injection of polymethylmethacrylate. Chest radiograph and computed tomography confirmed the presence of the cement in the pulmonary artery. The patient was treated with anticoagulants, inhaled nitric oxide, diuretics, antibiotics, and eventually pulmonary embolectomy. She died 20 days after the vertebroplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Cited by
Vertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies
Hulme, P. A., Krebs, J., Ferguson, S. J., & Berlemann, U. (2006) · Spine · doi:10.1097/01.brs.0000229254.89952.6b · Cited by 754
Eck, J. C., Nachtigall, D., Humphreys, S. C., & Hodges, S. D. (2008) · The Spine Journal · doi:10.1016/j.spinee.2007.04.004 · Cited by 354
Metadata
- Authors
- Yoo, K. Y., Jeong, S. W., Yoon, W., & Lee, J.
- Venue
- Spine
- Published
- 2004-07
- Volume
- 29
- Issue
- 14
- Pages
- E294-E297
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2024906019
- Cited by
- 184
- References
- 1
- FWCI
- 12.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute Respiratory Distress Syndrome Associated With Pulmonary Cement Embolism Following Percutaneous Vertebroplasty With Polymethylmethacrylate. https://app.cochat.ai/papers/10.1097/01.brs.0000131211.87594.b0
- The paper
- Yoo, K. Y., Jeong, S. W., Yoon, W., & Lee, J. (2004). Acute Respiratory Distress Syndrome Associated With Pulmonary Cement Embolism Following Percutaneous Vertebroplasty With Polymethylmethacrylate. Spine. https://doi.org/10.1097/01.brs.0000131211.87594.b0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.