Long-term Results of One-Level Lumbar Arthroplasty: Minimum 10-Year Follow-up of the CHARITÉ Artificial Disc in 106 Patients
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: A retrospective chart and radiographic review. OBJECTIVES: To determine the long-term clinical results, radiographic results, and incidence of complications in a large patient cohort with one-level lumbar total disc replacement (TDR). SUMMARY OF BACKGROUND DATA: Prior authors have described short-term, mid-term, and long-term clinical and radiographic results in patients with lumbar TDR with highly variable results. METHODS: From January 1989 to November 1995, 108 patients, with a mean age of 36.4 years, underwent lumbar TDR with the CHARITE Artificial Disc, with 106 available for follow-up. A modified Stauffer-Coventry scale was used to determine clinical outcome. Return to work, work level, and the incidence of complications were assessed. Dynamic lateral flexion-extension and lateral bending radiographs were performed and segmental range of motion (ROM) was measured using the Cobb method. RESULTS: Mean follow-up time was 13.2 years (range, 10-16.8 years). Of the 106 patients, 87 (82.1%) had either an excellent or good clinical outcome. Of the 96 patients working before surgery, 86 returned to work (89.6%), including 77.8% of patients with hard labor level employment (28 of 36) returning to the same level of work. The mean ROM in flexion-extension was 10.1 degrees , in lateral bending it was 4.4 degrees , and 90.6% of implanted prostheses were still mobile. Eight patients (7.5%) required posterior instrumented fusion. There were 5 cases (4.6%) of postoperative facet arthrosis, 3 cases (2.8%) of subsidence, 3 cases (2.8%) of adjacent-level disease, and 2 cases (1.9%) of core subluxation. CONCLUSIONS: This retrospective study demonstrates the safety and efficacy of the CHARITE Artificial Disc at one level, either L4-L5 or L5-S1, in the long-term. Clinical outcomes and the rate of return to work were excellent overall. The rate of adjacent-level disease requiring surgical intervention was considerably lower (2.8%) compared with reports in the literature for lumbar fusion. As with any surgical procedure, proper indications play a pivotal role in clinical success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ADJACENT SEGMENT DEGENERATION IN THE LUMBAR SPINE
GHISELLI, G., WANG, J. C., BHATIA, N. N., HSU, W. K., & DAWSON, E. G. (2004) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200407000-00020 · Cited by 766
Blumenthal, S., McAfee, P. C., Guyer, R. D., Hochschuler, S. H., Geisler, F. H., Holt, R. T., Garcia, R., Regan, J. J., & Ohnmeiss, D. D. (2005) · Spine · doi:10.1097/01.brs.0000170587.32676.0e · Cited by 586
Complications of Artificial Disc Replacement: A Report of 27 Patients with the SB Charité Disc
van Ooij, A., Oner, F. C., & Verbout, A. J. (2003) · Journal of Spinal Disorders & Techniques · doi:10.1097/00024720-200308000-00009 · Cited by 365
The Fate of the Adjacent Motion Segments After Lumbar Fusion
Gillet, P. (2003) · Journal of Spinal Disorders & Techniques · doi:10.1097/00024720-200308000-00005 · Cited by 333
Clinical and Radiological Outcomes With the Charité™ Artificial Disc: A 10-Year Minimum Follow-Up
Lemaire, J.-P., Carrier, H., Ali, E.-H. S., Skalli, W., & Lavaste, F. (2005) · Journal of Spinal Disorders & Techniques · doi:10.1097/01.bsd.0000172361.07479.6b · Cited by 282
Putzier, M., Funk, J. F., Schneider, S. V., Gross, C., Tohtz, S. W., Khodadadyan-Klostermann, C., Perka, C., & Kandziora, F. (2006) · European Spine Journal · doi:10.1007/s00586-005-1022-3 · Cited by 218
Geisler, F. H., Blumenthal, S. L., Guyer, R. D., McAfee, P. C., Regan, J. J., Johnson, J. P., & Mullin, B. B. (2004) · Journal of Neurosurgery Spine · doi:10.3171/spi.2004.1.2.0143 · Cited by 160
de Kleuver, M., Öner, F. C., & Jacobs, W. C. H. (2003) · European Spine Journal · doi:10.1007/s00586-002-0500-0 · Cited by 136
Revisability of the CHARITÉ Artificial Disc Replacement
McAfee, P. C., Geisler, F. H., Saiedy, S., Moore, S. V., Regan, J. J., Guyer, R. D., Blumenthal, S. L., Fedder, I. L., Tortolani, P. J., & Cunningham, B. W. (2006) · Spine · doi:10.1097/01.brs.0000217689.08487.a8 · Cited by 128 · cited 2×
“The topic of Charité Artificial Disc revision has been addressed by a number of authors, most recently by McAfee et al.31,32 The nonkeeled design of the Charité prosthesis allows for removal without sacrificing vertebral bone, although the primary revision approach is a posterior instrumented fusion unless neural or…”
BackgroundMirza, S. K. (2005) · Spine · doi:10.1097/01.brs.0000171806.30401.40 · Cited by 40
Cited by
Chou, R., Loeser, J. D., Owens, D. K., Rosenquist, R. W., Atlas, S. J., Baisden, J., Carragee, E. J., Grabois, M., Murphy, D. R., Resnick, D. K., et al. (2009) · Spine · doi:10.1097/brs.0b013e3181a1390d · Cited by 581
Biomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Chou, R., Baisden, J., Carragee, E. J., Resnick, D. K., Shaffer, W. O., & Loeser, J. D. (2009) · Spine · doi:10.1097/brs.0b013e3181a105fc · Cited by 456
Guyer, R. D., McAfee, P. C., Banco, R. J., Bitan, F. D., Cappuccino, A., Geisler, F. H., Hochschuler, S. H., Holt, R. T., Jenis, L. G., Majd, M. E., et al. (2009) · The Spine Journal · doi:10.1016/j.spinee.2008.08.007 · Cited by 296
Xia, X.-P., Chen, H.-L., & Cheng, H.-B. (2013) · Spine · doi:10.1097/brs.0b013e318273a2ea · Cited by 219
Hellum, C., Johnsen, L. G., Storheim, K., Nygaard, O. P., Brox, J. I., Rossvoll, I., Ro, M., Sandvik, L., Grundnes, O., & and the Norwegian Spine Study Group (2011) · BMJ · doi:10.1136/bmj.d2786 · Cited by 116
Metadata
- Authors
- David, T.
- Venue
- Spine
- Published
- 2007-03
- Volume
- 32
- Issue
- 6
- Pages
- 661-666
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2011710488
- Cited by
- 207
- References
- 10
- FWCI
- 15.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.