Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 282

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Clinical and Radiological Outcomes With the Charité™ Artificial Disc: A 10-Year Minimum Follow-Up

Lemaire, Jean-Philippe, Carrier, Hélène, Ali, El-Hadi Sari, Skalli, Waffa, Lavaste, François·2005·Journal of Spinal Disorders & Techniques

Abstract

This is the first report of clinical and radiologic outcomes for the CHARITE artificial disc with a minimum follow-up of 10 years. A total of 107 patients indicated for total lumbar disc replacement were implanted with the CHARITE prosthesis. Of these 107, 100 were followed for a minimum of 10 years (range 10-13.4 years). A total of 147 prostheses were implanted with 54 one-level and 45 two-level procedures and 1 three-level procedure. The prostheses were placed through a standard anterior retroperitoneal approach. Clinically, 62% had an excellent outcome, 28% had a good outcome, and 10% had a poor outcome. Of the 95 eligible to return to work, 88 (91.5%) either returned to the same job as prior to surgery or a different job. These included 63.2% (12) of those working in heavy labor employment returning to the same job. Mean flexion/extension motion was 10.3 degrees for all levels (12.0 degrees at L3-L4, 9.6 degrees at L4-L5, 9.2 degrees at L5-S1). Mean lateral motion was 5.4 degrees . In the sagittal plane, 9 (6.1%) were anterior of geometric center, 50 (34.0%) were centered, and 88 (59.9%) were posterior of center. In the frontal plane, 110 (75%) were centered, and 37 (25%) were noted to be lateral to center. Slight subsidence was observed in two patients, but they did not require further surgery. No subluxation of the prostheses and no cases of spontaneous arthrodesis were identified. There was one case of disc height loss of 1 mm. Five patients required a secondary posterior arthrodesis. A good or excellent clinical outcome rate of 90% and a return to work rate of 91.5% compare favorably with results described in the literature for fusion for the treatment of lumbar degenerative disc disease. With a minimum follow-up of 10 years, the CHARITE artificial disc demonstrated excellent flexion/extension and lateral range of motion with no significant complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.bsd.0000172361.07479.6b

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 282

Metadata

Authors
Lemaire, J.-P., Carrier, H., Ali, E.-H. S., Skalli, W., & Lavaste, F.
Venue
Journal of Spinal Disorders & Techniques
Published
2005-08
Volume
18
Issue
4
Pages
353-359
ISSN
1536-0652 (ISSN-L)
OpenAlex
W2072691284
Cited by
282
References
11
FWCI
17.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical and Radiological Outcomes With the Charité™ Artificial Disc: A 10-Year Minimum Follow-Up. https://app.cochat.ai/papers/10.1097/01.bsd.0000172361.07479.6b
The paper
Lemaire, J.-P., Carrier, H., Ali, E.-H. S., Skalli, W., & Lavaste, F. (2005). Clinical and Radiological Outcomes With the Charité™ Artificial Disc: A 10-Year Minimum Follow-Up. Journal of Spinal Disorders & Techniques. https://doi.org/10.1097/01.bsd.0000172361.07479.6b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.