Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement System: Two-Year Results From a Food and Drug Administration Investigational Device Exemption Clinical Trial

Brantigan, John W., Steffee, Arthur D., Lewis, Mary L., Quinn, Linda M., Persenaire, J. Maarten·2000·Spine

Abstract

STUDY DESIGN: A carbon fiber-reinforced polymer cage implant filled with autologous bone was designed to separate the mechanical and biologic functions of posterior lumbar interbody fusion. OBJECTIVES: To test the safety and efficacy of the carbon cage with pedicle screw fixation in a 2-year prospective study performed at six centers under a protocol approved by the Food and Drug Administration, and to present the data supporting the Food and Drug Administration approved indications. SUMMARY OF BACKGROUND DATA: The success of posterior lumbar interbody fusion has been limited by mechanical and biologic deficiencies of the donor bone. Some failures of pedicle screw fixation may be attributable to the absence of adequate load sharing through the anterior column. Combining an interbody fusion device with pedicle screw fixation may address some limitations of posterior lumbar interbody fusion or pedicle screw fixation in cases that are more complex mechanically. METHODS: This clinical study of posterior lumbar interbody fusion with pedicle screw fixation involved a prospective group of 221 patients. RESULTS: Fusion success was achieved in 176 (98.9%) of 178 patients. In the management of degenerative disc disease in patients with prior failed discectomy surgery, clinical success was achieved in 79 (86%) of 92 patients, and radiographic bony arthrodesis in 91 (100%) of 91 patients. Disc space height, averaging 7.9 mm before surgery, was increased to 12.3 mm at surgery and maintained at 11.7 mm at 2 years. Fusion success was notdiminished over multiple fusion levels. These results were significantly better than those reported in prior literature. Although significant surgical complications occurred, those attributable to the implant devices occurred less frequently and generally were minor. CONCLUSIONS: The Brantigan I/F Cage for posterior lumbar interbody fusion and the Variable Screw Placement System are safe and effective for the management of degenerative disc disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-200006010-00017

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Metadata

Authors
Brantigan, J. W., Steffee, A. D., Lewis, M. L., Quinn, L. M., & Persenaire, J. M.
Venue
Spine
Published
2000-06
Volume
25
Issue
11
Pages
1437-1446
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2045139735
Cited by
348
References
25
FWCI
10.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement System: Two-Year Results From a Food and Drug Administration Investigational Device Exemption Clinical Trial. https://app.cochat.ai/papers/10.1097/00007632-200006010-00017
The paper
Brantigan, J. W., Steffee, A. D., Lewis, M. L., Quinn, L. M., & Persenaire, J. M. (2000). Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement System: Two-Year Results From a Food and Drug Administration Investigational Device Exemption Clinical Trial. Spine. https://doi.org/10.1097/00007632-200006010-00017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.