CoChat

High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients

Derdak, Stephen · 2003 · Critical Care Medicine
Cited by 222

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: High-frequency oscillatory ventilation (HFOV) using an open-lung strategy has been demonstrated to improve oxygenation in neonatal and pediatric respiratory failure, without increasing barotrauma. Animal studies using small (<4 mm) endotracheal tubes have shown reduced histopathologic evidence of lung injury and inflammatory mediator release, suggesting reduced ventilator-induced lung injury. CLINICAL STUDIES: During the last decade, case reports and observational studies of HFOV in patients failing conventional ventilation strategies have suggested improved oxygenation in adult patients with severe acute respiratory distress syndrome. These reports have also suggested that early (2 days) initiation of HFOV is more likely to result in survival than delayed initiation (>7 days). A recently published randomized, controlled trial in acute respiratory distress syndrome patients (n = 148) comparing HFOV with a pressure-control ventilation strategy (Pao(2)/Fio(2) ratio of 10 cm H(2)O) demonstrated early (<16 hrs) improvement in Pao(2)/Fio(2) (p =.008) in the HFOV group but no significant difference in oxygenation index between the two groups during the initial 72 hrs of treatment. Thirty-day mortality was 37% in the HFOV group and 52% in the conventional ventilation group (p =.102). There was no significant difference between treatment groups in the prevalence of barotrauma, hemodynamic instability, or mucus plugging. This study suggests that HFOV is as effective and safe as the conventional strategy to which it was compared. CLINICAL APPLICATION: For clinical use in adults, a trial of HFOV may be considered when Fio(2) requirements exceed 60% and mean airway pressure is approaching 20 cm H(2)O or higher (or, alternatively, positive end-expiratory pressure of >15 cm H(2)O). It is currently unknown whether initiating HFOV at a lower severity threshold would result in reduced ventilator-associated lung injury or mortality. FUTURE DIRECTIONS: Future studies should compare different algorithms of applying HFOV to determine the optimal techniques for achieving oxygenation and ventilation, while minimizing ventilator-associated lung injury. The potential role of adjunctive therapies used with HFOV (e.g., prone ventilation, inhaled nitric oxide, aerosolized vasodilators, liquid ventilation) will require further research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000057910.50618.eb

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 222

Metadata

Authors
Derdak, S.
Venue
Critical Care Medicine
Published
2003-04
Volume
31
Issue
Supplement
Pages
S317-S323
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2061138775
Cited by
222
References
2
FWCI
9.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients. https://app.cochat.ai/papers/10.1097/01.ccm.0000057910.50618.eb
The paper
Derdak, S. (2003). High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000057910.50618.eb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.