The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A new pumpless extracorporeal interventional lung assist in critical hypoxemia/hypercapnia*
Open accessAbstract
OBJECTIVE: Pump-driven extracorporeal gas exchange systems have been advocated in patients suffering from severe acute respiratory distress syndrome who are at risk for life-threatening hypoxemia and/or hypercapnia. This requires extended technical and staff support. DESIGN: We report retrospectively our experience with a new pumpless extracorporeal interventional lung assist (iLA) establishing an arteriovenous shunt as the driving pressure. SETTING: University hospital. PATIENTS: Ninety patients with acute respiratory distress syndrome. INTERVENTIONS: Interventional lung assist was inserted in 90 patients with acute respiratory distress syndrome. MEASUREMENTS AND MAIN RESULTS: Oxygenation improvement, carbon dioxide elimination, hemodynamic variables, and the amount of vasopressor substitution were reported before, 2 hrs after, and 24 hrs after implementation of the system. Interventional lung assist led to an acute and moderate increase in arterial oxygenation (Pao2/Fio2 ratio 2 hrs after initiation of iLA [median and interquartile range], 82 mm Hg [64-103]) compared with pre-iLA (58 mm Hg [47-78], p < .05). Oxygenation continued to improve for 24 hrs after implementation (101 mm Hg [74-142], p < .05). Hypercapnia was promptly and markedly reversed by iLA within 2 hrs (Paco2, 36 mm Hg [30-44]) in comparison with before (60 mm Hg [48-80], p < .05], which allowed a less aggressive ventilation. For hemodynamic stability, all patients received continuous norepinephrine infusion. The incidence of complications was 24.4%, mostly due to ischemia in a lower limb. Thirty-seven of 90 patients survived, creating a lower mortality rate than expected from the Sequential Organ Failure Assessment score. CONCLUSIONS: Interventional lung assist might provide a sufficient rescue measure with easy handling properties and low cost in patients with severe acute respiratory distress syndrome and persistent hypoxia/hypercapnia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
The Acute Respiratory Distress Syndrome
Matthay, M. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605303342209 · Cited by 4,923
The Acute Respiratory Distress Syndrome
Ware, L. B., & Matthay, M. A. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421806 · Cited by 4,666
Zapol, W. M. (1979) · JAMA · doi:10.1001/jama.242.20.2193 · Cited by 1,220
Zapol, W. M. (1979) · JAMA · doi:10.1001/jama.1979.03300200023016 · Cited by 1,184
Morris, A. H., Wallace, C. J., Menlove, R. L., Clemmer, T. P., Orme, J. F., Weaver, L. K., Dean, N. C., Thomas, F., East, T. D., Pace, N. L., et al. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.2.8306022 · Cited by 968
Extracorporeal Membrane Oxygenation (ECMO) Cardiopulmonary Support in Infancy
Bartlett, R. H., Gazzaniga, A. B., Jefferies, M. R., Huxtable, R. F., Haiduc, N. J., & Fong, S. W. (1979) · The Journal of ExtraCorporeal Technology · doi:10.1051/ject/197911126 · Cited by 519
Prone position in mechanically ventilated patients with severe acute respiratory failure.
Chatte, G., Sab, J. M., Dubois, J. M., Sirodot, M., Gaussorgues, P., & Robert, D. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.2.9032181 · Cited by 360
Extracorporeal Life Support: The University of Michigan Experience
Bartlett, R. H., Roloff, D. W., Custer, J. R., Younger, J. G., & Hirschl, R. B. (2000) · JAMA · doi:10.1001/jama.283.7.904 · Cited by 351
Lewandowski, K., Rossaint, R., Pappert, D., Gerlach, H., Slama, K.-J., Weidemann, H., Frey, D. J. M., Hoffmann, O., Keske, U., & Falke, K. J. (1997) · Intensive Care Medicine · doi:10.1007/s001340050418 · Cited by 287
Cited by
Extracorporeal Membrane Oxygenation for ARDS in Adults
Brodie, D., & Bacchetta, M. (2011) · New England Journal of Medicine · doi:10.1056/nejmct1103720 · Cited by 836
Formal guidelines: Management of acute respiratory distress syndrome.
Papazian, L., Aubron, C., Brochard, L., Chiche, J.-D., Combes, A., Dreyfuss, D., Forel, J.-M., Guérin, C., Jaber, S., Mekontso-Dessap, A., et al. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0540-9 · Cited by 761
Has Mortality from Acute Respiratory Distress Syndrome Decreased over Time?: A Systematic Review
Phua, J., Badia, J. R., Adhikari, N. K. J., Friedrich, J. O., Fowler, R. A., Singh, J. M., Scales, D. C., Stather, D. R., Li, A., Jones, A., et al. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200805-722oc · Cited by 727
Terragni, P. P., Del Sorbo, L., Mascia, L., Urbino, R., Martin, E. L., Birocco, A., Faggiano, C., Quintel, M., Gattinoni, L., & Ranieri, V. M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181b764d2 · Cited by 577
Bein, T., Weber-Carstens, S., Goldmann, A., Müller, T., Staudinger, T., Brederlau, J., Muellenbach, R., Dembinski, R., Graf, B. M., Wewalka, M., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2787-6 · Cited by 575
Self-citation
Metadata
- Authors
- Bein, T., Weber, F., Philipp, A., Prasser, C., Pfeifer, M., Schmid, F.-X., Butz, B., Birnbaum, D., Taeger, K., & Schlitt, H. J.
- Venue
- Critical Care Medicine
- Published
- 2006-05
- Volume
- 34
- Issue
- 5
- Pages
- 1372-1377
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2121474530
- Cited by
- 345
- References
- 21
- FWCI
- 21.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new pumpless extracorporeal interventional lung assist in critical hypoxemia/hypercapnia*. https://app.cochat.ai/papers/10.1097/01.ccm.0000215111.85483.bd
- The paper
- Bein, T., Weber, F., Philipp, A., Prasser, C., Pfeifer, M., Schmid, F.-X., Butz, B., Birnbaum, D., Taeger, K., & Schlitt, H. J. (2006). A new pumpless extracorporeal interventional lung assist in critical hypoxemia/hypercapnia*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000215111.85483.bd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.