The DOI matches its Crossref record.
Continuous positive airway pressure delivered with a “helmet”: Effects on carbon dioxide rebreathing*
Abstract
OBJECTIVE: The "helmet" has been used as a novel interface to deliver noninvasive ventilation without applying direct pressure on the face. However, due to its large volume, the helmet may predispose to CO2 rebreathing. We hypothesized that breathing with the helmet is similar to breathing in a semiclosed environment, and therefore the PCO2 inside the helmet is primarily a function of the subject's CO2 production and the flow of fresh gas through the helmet. DESIGN: Human volunteer study. SETTING: Laboratory in a university teaching hospital. SUBJECTS: Eight healthy volunteers. INTERVENTIONS: We delivered continuous positive airway pressure (CPAP) with the helmet under a variety of ventilatory conditions in a lung model and in volunteers. MEASUREMENTS AND MAIN RESULTS: Gas flow and CO2 concentration at the airway were measured continuously. End-tidal PCO2, CO2 production, and ventilatory variables were subsequently computed. We found that a) when CPAP was delivered with a ventilator, the inspired CO2 of the volunteers was high (12.4 +/- 3.2 torr [1.7 +/- 0.4 kPa]); b) when CPAP was delivered with a continuous high flow system, inspired CO2 of the volunteers was low (2.5 +/- 1.2 torr [0.3 +/- 0.2 kPa]); and c) the inspired CO2 calculated mathematically for a semiclosed system model of CO2 rebreathing was highly correlated with the values measured in a lung model (r = .97, slope = 0.92, intercept = -1.17, p < .001) and in the volunteers (r = .94, slope = 0.96, intercept = 0.90, p < .001). CONCLUSIONS: a) The helmet predisposes to CO2 rebreathing and should not be used to deliver CPAP with a ventilator; b) continuous high flow minimizes CO2 rebreathing during CPAP with the helmet; and c) minute ventilation and Pco2 should be monitored during CPAP with the helmet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patel, B. K., Wolfe, K. S., Pohlman, A. S., Hall, J. B., & Kress, J. P. (2016) · JAMA · doi:10.1001/jama.2016.6338 · Cited by 545
Carron, M., Freo, U., BaHammam, A. S., Dellweg, D., Guarracino, F., Cosentini, R., Feltracco, P., Vianello, A., Ori, C., & Esquinas, A. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet070 · Cited by 312
Grieco, D. L., Maggiore, S. M., Roca, O., Spinelli, E., Patel, B. K., Thille, A. W., Barbas, C. S. V., de Acilu, M. G., Cutuli, S. L., Bongiovanni, F., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06459-2 · Cited by 286
The right interface for the right patient in noninvasive ventilation: a systematic review
Pierucci, P., Portacci, A., Carpagnano, G. E., Banfi, P., Crimi, C., Misseri, G., & Gregoretti, C. (2022) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2022.2121706 · Cited by 40
Metadata
- Authors
- Taccone, P., Hess, D., Caironi, P., & Bigatello, L. M.
- Venue
- Critical Care Medicine
- Published
- 2004-10
- Volume
- 32
- Issue
- 10
- Pages
- 2090-2096
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2121215275
- Cited by
- 181
- References
- 0
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous positive airway pressure delivered with a “helmet”: Effects on carbon dioxide rebreathing*. https://app.cochat.ai/papers/10.1097/01.ccm.0000142577.63316.c0
- The paper
- Taccone, P., Hess, D., Caironi, P., & Bigatello, L. M. (2004). Continuous positive airway pressure delivered with a “helmet”: Effects on carbon dioxide rebreathing*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000142577.63316.c0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.