CoChat

Clinical trial of a novel surface cooling system for fever control in neurocritical care patients*

Mayer, Stephan A., Kowalski, Robert G., Presciutti, Mary, Ostapkovich, Noeleen D., McGann, Elaine, Fitzsimmons, Brian-Fred, Yavagal, Dileep R., Du, Y Evelyn, Naidech, Andrew M., Janjua, Nazli A., Claassen, Jan, Kreiter, Kurt T., Parra, Augusto, Commichau, Christopher · 2004 · Critical Care Medicine
Cited by 244

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare the efficacy of a novel water-circulating surface cooling system with conventional measures for treating fever in neuro-intensive care unit patients. DESIGN: Prospective, unblinded, randomized controlled trial. SETTING: Neurologic intensive care unit in an urban teaching hospital. PATIENTS: Forty-seven patients, the majority of whom were mechanically ventilated and sedated, with fever > or =38.3 degrees C for >2 consecutive hours after receiving 650 mg of acetaminophen. INTERVENTIONS: Subjects were randomly assigned to 24 hrs of treatment with a conventional water-circulating cooling blanket placed over the patient (Cincinnati SubZero, Cincinnati OH) or the Arctic Sun Temperature Management System (Medivance, Louisville CO), which employs hydrogel-coated water-circulating energy transfer pads applied directly to the trunk and thighs. MEASUREMENTS AND MAIN RESULTS: Diagnoses included subarachnoid hemorrhage (60%), cerebral infarction (23%), intracerebral hemorrhage (11%), and traumatic brain injury (4%). The groups were matched in terms of baseline variables, although mean temperature was slightly higher at baseline in the Arctic Sun group (38.8 vs. 38.3 degrees C, p = .046). Compared with patients treated with the SubZero blanket (n = 24), Arctic Sun-treated patients (n = 23) experienced a 75% reduction in fever burden (median 4.1 vs. 16.1 C degrees -hrs, p = .001). Arctic Sun-treated patients also spent less percent time febrile (T > or =38.3 degrees C, 8% vs. 42%, p < .001), spent more percent time normothermic (T < or =37.2 degrees C, 59% vs. 3%, p < .001), and attained normothermia faster than the SubZero group median (2.4 vs. 8.9 hrs, p = .008). Shivering occurred more frequently in the Arctic Sun group (39% vs. 8%, p = .013). CONCLUSION: The Arctic Sun Temperature Management System is superior to conventional cooling-blanket therapy for controlling fever in critically ill neurologic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000147441.39670.37

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

Metadata

Authors
Mayer, S. A., Kowalski, R. G., Presciutti, M., Ostapkovich, N. D., McGann, E., Fitzsimmons, B.-F., Yavagal, D. R., Du, Y. E., Naidech, A. M., Janjua, N. A., Claassen, J., Kreiter, K. T., Parra, A., & Commichau, C.
Venue
Critical Care Medicine
Published
2004-12
Volume
32
Issue
12
Pages
2508-2515
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1988222409
Cited by
244
References
29
FWCI
12.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.