CoChat

Transient hemodynamic effects of recruitment maneuvers in three experimental models of acute lung injury*

Lim, Sung-Chul, Adams, Alexander B., Simonson, Dana A., Dries, David J., Broccard, Alain F., Hotchkiss, John R., Marini, John J. · 2004 · Critical Care Medicine
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Elevated lung volumes and increased pleural pressures associated with recruitment maneuvers (RM) may adversely affect pulmonary vascular resistance and cardiac filling or performance. We investigated the hemodynamic consequences of three RM techniques after inducing acute lung injury. DESIGN: Prospective, randomized, controlled experimental study. SETTING: Hospital research laboratory. SUBJECTS: Thirteen anesthetized, mechanically ventilated pigs. INTERVENTIONS: We induced three types of acute lung injury: oleic acid injury (n = 4); ventilator-induced lung injury (n = 4); and pneumonia (n = 5). All three models were designed to initiate a similar severity of oxygenation impairment. RM methods tested were sustained inflation, incremental positive end-expiratory pressure (PEEP) with a limited peak pressure, and pressure-controlled ventilation with increased PEEP and a fixed driving pressure. From a baseline PEEP of 8 cm H2O, all interventions were tested using post-RM PEEP levels of 8, 12, and 16 cm H2O. Cardiac output by thermodilution and systemic and pulmonary artery pressures were measured frequently during the RM and for 15 mins after its completion. MEASUREMENTS AND MAIN RESULTS: During the RM, cardiac output decreased to a greater extent in the pneumonia model (0.49 of baseline cardiac output) than in the oleic acid injury (0.67 of baseline) or ventilator-induced lung injury (0.79 of baseline) models. Cardiac output recovered to the baseline value by 5 mins post-RM in oleic acid injury and ventilator-induced lung injury models. However, cardiac output remained decreased 15 mins post-RM in the pneumonia model. There were no differences in hemodynamic parameters among RM methods in oleic acid injury and ventilator-induced lung injury models. In the pneumonia model, however, cardiac output decreased to a greater extent during the RM with sustained inflation (to 0.33 of baseline cardiac output) compared with pressure-controlled ventilation (to 0.68 of baseline). CONCLUSIONS: We conclude that RM transiently but profoundly depressed cardiac output in three models of acute lung injury. The results imply that a lung recruiting maneuver should be used with caution, especially when using sustained inflation in the setting of pneumonia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000147444.58070.72

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 161

Metadata

Authors
Lim, S.-C., Adams, A. B., Simonson, D. A., Dries, D. J., Broccard, A. F., Hotchkiss, J. R., & Marini, J. J.
Venue
Critical Care Medicine
Published
2004-12
Volume
32
Issue
12
Pages
2378-2384
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1967047843
Cited by
161
References
1
FWCI
6.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transient hemodynamic effects of recruitment maneuvers in three experimental models of acute lung injury*. https://app.cochat.ai/papers/10.1097/01.ccm.0000147444.58070.72
The paper
Lim, S.-C., Adams, A. B., Simonson, D. A., Dries, D. J., Broccard, A. F., Hotchkiss, J. R., & Marini, J. J. (2004). Transient hemodynamic effects of recruitment maneuvers in three experimental models of acute lung injury*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000147444.58070.72

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.