Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Sedation algorithm in critically ill patients without acute brain injury

De Jonghe, Bernard, Bastuji-Garin, Sylvie, Fangio, Pascal, Lacherade, Jean-Claude, Jabot, Julien, Appéré-De-Vecchi, Corinne, Rocha, Nathalie, Outin, Hervé·2005·Critical Care Medicine

Abstract

OBJECTIVE: To determine whether use of a sedation algorithm to promote a high level of tolerance to the intensive care environment and preserve consciousness affected time to arousal and duration of mechanical ventilation in patients without acute brain injury. DESIGN: Two-phase, prospective, controlled study. SETTING: University-affiliated medical intensive care unit. PATIENTS: : Patients without acute brain injury requiring mechanical ventilation for at least 24 hrs. INTERVENTIONS: During the control phase, sedatives and analgesics were adjusted according to the physician's decision. During the algorithm phase, sedatives and analgesics were adjusted according to an algorithm developed by a multidisciplinary team including nurses and physicians. The algorithm was based on regular assessments of consciousness and tolerance to the intensive care unit environment using the Adaptation to Intensive Care Environment instrument and was designed to achieve tolerance and maintain a high level of consciousness. Standard practices, including weaning from the ventilator, were the same during both study phases. MEASUREMENTS AND MAIN RESULTS: A total of 102 patients were enrolled (control group, n = 54; algorithm group, n = 48). Median duration of mechanical ventilation was significantly shorter in the algorithm group (4.4 days [interquartile range, 2.1-9.8]) compared with the control group (10.3 days [3.5-17.2], p = .014), representing a 57.3% reduction. In Cox multivariate analysis, the risk of remaining on mechanical ventilation was 0.48 times (95% confidence interval, 0.29-0.78) lower for algorithm patients compared with controls. The median time to arousal was also significantly shorter in patients in the algorithm group (2 days [2-5]) compared with the control group (4 days [2-9], p = .006). CONCLUSIONS: The use of a sedation algorithm to promote tolerance to the intensive care environment and preserve consciousness in patients without acute brain injury resulted in a marked decrease in the duration of mechanical ventilation. This reduction was at least partly attributable to a shorter time to arousal after initiation of mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000150268.04228.68

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 245

Metadata

Authors
De Jonghe, B., Bastuji-Garin, S., Fangio, P., Lacherade, J.-C., Jabot, J., Appéré-De-Vecchi, C., Rocha, N., & Outin, H.
Venue
Critical Care Medicine
Published
2005-01
Volume
33
Issue
1
Pages
120-127
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1998818484
Cited by
245
References
1
FWCI
13.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sedation algorithm in critically ill patients without acute brain injury. https://app.cochat.ai/papers/10.1097/01.ccm.0000150268.04228.68
The paper
De Jonghe, B., Bastuji-Garin, S., Fangio, P., Lacherade, J.-C., Jabot, J., Appéré-De-Vecchi, C., Rocha, N., & Outin, H. (2005). Sedation algorithm in critically ill patients without acute brain injury. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000150268.04228.68

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.