Sedation algorithm in critically ill patients without acute brain injury
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether use of a sedation algorithm to promote a high level of tolerance to the intensive care environment and preserve consciousness affected time to arousal and duration of mechanical ventilation in patients without acute brain injury. DESIGN: Two-phase, prospective, controlled study. SETTING: University-affiliated medical intensive care unit. PATIENTS: : Patients without acute brain injury requiring mechanical ventilation for at least 24 hrs. INTERVENTIONS: During the control phase, sedatives and analgesics were adjusted according to the physician's decision. During the algorithm phase, sedatives and analgesics were adjusted according to an algorithm developed by a multidisciplinary team including nurses and physicians. The algorithm was based on regular assessments of consciousness and tolerance to the intensive care unit environment using the Adaptation to Intensive Care Environment instrument and was designed to achieve tolerance and maintain a high level of consciousness. Standard practices, including weaning from the ventilator, were the same during both study phases. MEASUREMENTS AND MAIN RESULTS: A total of 102 patients were enrolled (control group, n = 54; algorithm group, n = 48). Median duration of mechanical ventilation was significantly shorter in the algorithm group (4.4 days [interquartile range, 2.1-9.8]) compared with the control group (10.3 days [3.5-17.2], p = .014), representing a 57.3% reduction. In Cox multivariate analysis, the risk of remaining on mechanical ventilation was 0.48 times (95% confidence interval, 0.29-0.78) lower for algorithm patients compared with controls. The median time to arousal was also significantly shorter in patients in the algorithm group (2 days [2-5]) compared with the control group (4 days [2-9], p = .006). CONCLUSIONS: The use of a sedation algorithm to promote tolerance to the intensive care environment and preserve consciousness in patients without acute brain injury resulted in a marked decrease in the duration of mechanical ventilation. This reduction was at least partly attributable to a shorter time to arousal after initiation of mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
Kress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981
Jacobi, J., Fraser, G. L., Coursin, D. B., Riker, R. R., Fontaine, D., Wittbrodt, E. T., Chalfin, D. B., Masica, M. F., Bjerke, H. S., Coplin, W. M., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200201000-00020 · Cited by 1,895 · cited 1×
“To avoid oversedation and achieve tolerance to the ICU environment, levels of consciousness and tolerance need to be repeatedly measured and compared with specific patient-related goals (9).”
BackgroundA Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Ely, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation
Brook, A. D., Ahrens, T. S., Schaiff, R., Prentice, D., Sherman, G., Shannon, W., & Kollef, M. H. (1999) · Critical Care Medicine · doi:10.1097/00003246-199912000-00001 · Cited by 1,013 · cited 2×
“Whereas several studies have reported no effect or a negative effect of sedation algorithms on the duration of mechanical ventilation (10, 11), other large, randomized trials have shown a significant reduction associated with their use (12, 13).”
BackgroundEsley, E. W., Ly, E., Aker, M., Unagan, D. O. P. D., Urke, L. B., Mith, C. S., Atrick, P., Elly, T. K., Argaret, M., Ohnson, M. J., et al. (1996) · Cited by 950
The Use of Continuous IV Sedation Is Associated With Prolongation of Mechanical Ventilation
Kollef, M. H., Levy, N. T., Ahrens, T. S., Schaiff, R., Prentice, D., & Sherman, G. (1998) · Chest · doi:10.1378/chest.114.2.541 · Cited by 916 · cited 2×
“The median time to arousal was significantly shorter in the algorithm group (2 days (2–5)) than in the control group (4 days [2–9], p .”
BackgroundPropofol vs Midazolam for ICU Sedation
Hall, R. I., Sandham, D., Cardinal, P., Tweeddale, M., Moher, D., Wang, X., & Anis, A. H. (2001) · Chest · doi:10.1378/chest.119.4.1151 · Cited by 414
Sedation in the Intensive Care Unit: A Systematic Review
Ostermann, M. E., Keenan, S. P., Seiferling, R. A., & Sibbald, W. J. (2000) · JAMA · doi:10.1001/jama.283.11.1451 · Cited by 389 · cited 1×
“However, none of these studies were blinded, and weaning from the ventilator was not standardized (35, 36).”
BackgroundVenn, R. M., & Grounds, R. M. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.5.684 · Cited by 383 · cited 1×
“Although the recently developed dexmedetomidine seems to provide satisfactory control of intolerance to the ICU environment, with only minimal effects on consciousness and respiration (29), prospective comparative studies of dexmedetomidine and other sedative drugs have been performed in patients with short-term posto…”
BackgroundHerr, D. L., Sum-Ping, S. T. J., & England, M. (2003) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(03)00200-3 · Cited by 357 · cited 1×
“Although the recently developed dexmedetomidine seems to provide satisfactory control of intolerance to the ICU environment, with only minimal effects on consciousness and respiration (29), prospective comparative studies of dexmedetomidine and other sedative drugs have been performed in patients with short-term posto…”
BackgroundProlonged sedation due to accumulation of conjugated metabolites of midazolam
Bauer, T. M., Ritz, R., Haberthür, C., Haefeli, W. E., Scollo-Lavizzari, G., Ha, H. R., Hunkeler, W., & Sleight, A. J. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91209-6 · Cited by 334 · cited 2×
“The median time to arousal was significantly shorter in the algorithm group (2 days (2–5)) than in the control group (4 days [2–9], p .”
BackgroundFagon, J. Y., Chastre, J., Novara, A., Medioni, P., & Gibert, C. (1993) · Intensive Care Medicine · doi:10.1007/bf01720528 · Cited by 315 · cited 2×
“Baseline characteristics were similar in the two groups (Table 1) (18, 19).”
BackgroundMethodSedative and analgesic practice in the intensive care unit: the results of a European survey
Soliman, H. M., Mélot, C., & Vincent, J.-L. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.186 · Cited by 286 · cited 2×
“The median time to arousal was significantly shorter in the algorithm group (2 days (2–5)) than in the control group (4 days [2–9], p .”
BackgroundBarrientos-Vega, R., Sanchez-Soria, M. M., Morales-Garcia, C., Robas-Gomez, A., Cuena-Boy, R., & Ayensa-Rincon, A. (1997) · Critical Care Medicine · doi:10.1097/00003246-199701000-00009 · Cited by 286
HANSEN-FLASCHEN, J. H., BRAZINSKY, S., BASILE, C., & LANKIN, P. N. (1992) · Survey of Anesthesiology · doi:10.1097/00132586-199208000-00047 · Cited by 271
Propofol vs Midazolam in Short-, Medium-, and Long-term Sedation of Critically III Patients
Carrasco, G., Molina, R., Costa, J., Soler, J.-M., & Cabré, L. (1993) · Chest · doi:10.1378/chest.103.2.557 · Cited by 251
Hansen-Flaschen, J. H. (1991) · JAMA · doi:10.1001/jama.1991.03470200082040 · Cited by 250
Unplanned extubation: Risk factors of development and predictive criteria for reintubation
Chevron, V., Menard, J.-F., Richard, J.-C., Girault, C., Leroy, J., & Bonmarchand, G. (1998) · Critical Care Medicine · doi:10.1097/00003246-199806000-00026 · Cited by 240 · cited 1×
“However, although self-extubation has been associated with agitation and inadequate sedation (37, 38), this was not the case with our patients in the algorithm group, in which use of the algorithm allowed precise titration of sedatives and morphinics due to repeated assessments of tolerance to the ICU environment.”
ResultPham, L. H., Brun-Buisson, C., Legrand, P., Rauss, A., Verra, F., Brochard, L., & Lemaire, F. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.5_pt_1.1055 · Cited by 238 · cited 1×
“Diagnosis of ventilator-associated pneumonia was based on the presence of clinical criteria (20) and confirmed by bronchoalveolar lavage culture of 10(4) CFU/mL at 48 hrs after mechanical ventilation initiation.”
MethodBarr, J., Zomorodi, K., Bertaccini, E. J., Shafer, S. L., & Geller, E. (2001) · Anesthesiology · doi:10.1097/00000542-200108000-00007 · Cited by 209
Randomised trial of magnesium in in-hospital cardiac arrest
Thel, M. C., Armstrong, A. L., McNulty, S. E., Califf, R. M., & O'Connor, C. M. (1997) · The Lancet · doi:10.1016/s0140-6736(97)05048-4 · Cited by 202
Triltsch, A. E., Welte, M., von Homeyer, P., Groe, J., Genähr, A., Moshirzadeh, M., Sidiropoulos, A., Konertz, W., Kox, W. J., & Spies, C. D. (2002) · Critical Care Medicine · doi:10.1097/00003246-200205000-00009 · Cited by 199
De Jonghe, B., Cook, D., Griffith, L., Appere-de-Vecchi, C., Guyatt, G., Théron, V., Vagnerre, A., & Outin, H. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000084850.16444.94 · Cited by 186 · cited 1×
“This five-item instrument has shown satisfactory measurement properties in ICU patients, including validity, reproducibility, and responsiveness (17).”
MethodSelf-citationDevlin, J. W., Holbrook, A. M., & Fuller, H. D. (1997) · Annals of Pharmacotherapy · doi:10.1177/106002809703100604 · Cited by 160 · cited 1×
“Whereas several studies have reported no effect or a negative effect of sedation algorithms on the duration of mechanical ventilation (10, 11), other large, randomized trials have shown a significant reduction associated with their use (12, 13).”
BackgroundDiringer, M. N., Edwards, D. F., Aiyagari, V., & Hollingsworth, H. H. (2001) · Critical Care Medicine · doi:10.1097/00003246-200109000-00023 · Cited by 154
A Prospective Evaluation of Empiric versus Protocol‐Based Sedation and Analgesia
MacLaren, R., Plamondon, J. M., Ramsay, K. B., Rocker, G. M., Patrick, W. D., & Hall, R. I. (2000) · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.20.7.662.35172 · Cited by 110 · cited 1×
“Whereas several studies have reported no effect or a negative effect of sedation algorithms on the duration of mechanical ventilation (10, 11), other large, randomized trials have shown a significant reduction associated with their use (12, 13).”
BackgroundMultifocal necrotizing leukoencephalopathy in septic shock
Sharshar, T., Gray, F., Poron, F., Raphael, J. C., Gajdos, P., & Annane, D. (2002) · Critical Care Medicine · doi:10.1097/00003246-200210000-00031 · Cited by 102 · cited 1×
“Although clinical or infraclinical brain injury may occur during the ICU management of patients without acute brain injury at ICU admission, such as in patients with septic shock (14), the level of consciousness and time to extubation of patients without acute brain injury compared with those with acute brain injury a…”
BackgroundSedatives, Analgesics, and Paralytics in the Icu
Watling, S., Dasta, J. F., & Seidl, E. C. (1997) · Annals of Pharmacotherapy · doi:10.1177/106002809703100202 · Cited by 85
Walder, B., Elia, N., Henzi, I., Romand, J. R., & Tramèr, M. R. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00033 · Cited by 79 · cited 1×
“However, none of these studies were blinded, and weaning from the ventilator was not standardized (35, 36).”
BackgroundMechanical ventilation in patients with acute ischemic stroke: survival and outcome at one year
Santoli, F., Jonghe, B. D., Hayon, J., Tran, B., Piperaud, M., Merrer, J., & Outin, H. (2001) · Intensive Care Medicine · doi:10.1007/s001340100998 · Cited by 77 · cited 1×
“Furthermore, ICU mortality among patients with acute brain injury is very high, and death usually occurs early after ICU admission (15, 16).”
BackgroundSelf-citationThe relationship of sedation to deliberate self-extubation
Tung, A., Tadimeti, L., Caruana-Montaldo, B., Atkins, P., Mion, L. C., Palmer, R. M., Slomka, J., & Mendelson, W. B. (2001) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(00)00237-3 · Cited by 60
Cited by
Barr, J., Fraser, G. L., Puntillo, K., Ely, E. W., Gélinas, C., Dasta, J. F., Davidson, J. E., Devlin, J. W., Kress, J. P., Joffe, A. M., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182783b72 · Cited by 3,765
Schweickert, W. D., Pohlman, M. C., Pohlman, A. S., Nigos, C., Pawlik, A. J., Esbrook, C. L., Spears, L., Miller, M., Franczyk, M., Deprizio, D., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60658-9 · Cited by 3,339
Needham, D. M., Korupolu, R., Zanni, J. M., Pradhan, P., Colantuoni, E., Palmer, J. B., Brower, R. G., & Fan, E. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.01.002 · Cited by 731
Sedation and Delirium in the Intensive Care Unit
Reade, M. C., & Finfer, S. (2014) · New England Journal of Medicine · doi:10.1056/nejmra1208705 · Cited by 613
Payen, J.-F., Chanques, G., Mantz, J., Hercule, C., Auriant, I., Leguillou, J.-L., Binhas, M., Genty, C., Rolland, C., & Bosson, J.-L. (2007) · Anesthesiology · doi:10.1097/01.anes.0000264747.09017.da · Cited by 570
Metadata
- Authors
- De Jonghe, B., Bastuji-Garin, S., Fangio, P., Lacherade, J.-C., Jabot, J., Appéré-De-Vecchi, C., Rocha, N., & Outin, H.
- Venue
- Critical Care Medicine
- Published
- 2005-01
- Volume
- 33
- Issue
- 1
- Pages
- 120-127
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1998818484
- Cited by
- 245
- References
- 38
- FWCI
- 13.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.