The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Central venous catheterization
Abstract
OBJECTIVE: To provide current information related to central venous catheterization. DESIGN: Review of literature relevant to central venous catheterization and its indications, insertion techniques, and prevention of complications. RESULTS: Central venous catheterization can be lifesaving but is associated with complication rates of approximately 15%. Operator experience, familiarity with the advantages and disadvantages of the various catheterization sites, and strict attention to detail during insertion help in reducing mechanical complications associated with catheterization. Strict aseptic technique and proper catheter maintenance decrease the frequency of catheter-related infections. CONCLUSIONS: Appropriate catheter and site selection, sufficient operator experience, careful technique, and proper catheter maintenance with removal as soon as possible are associated with optimal outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Catheter Replacement of the Needle in Percutaneous Arteriography: A new technique
Seldinger, S. I. (1953) · Acta Radiologica · doi:10.3109/00016925309136722 · Cited by 3,270
Preventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Nosocomial infections in medical intensive care units in the United States
Richards, M. J., Edwards, J. R., Culver, D. H., & Gaynes, R. P. (1999) · Critical Care Medicine · doi:10.1097/00003246-199905000-00020 · Cited by 1,565
Merrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187
Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852
Maki, D. G., Alvarado, C. J., & Ringer, M. (1991) · The Lancet · doi:10.1016/0140-6736(91)90479-9 · Cited by 845
Bern, M. M., Lokich, J. J., Wallach, S. R., Bothe, A., Benotti, P. N., Arkin, C. F., Greco, F. A., Huberman, M., & Moore, C. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-76-3-112-6-423 · Cited by 788
Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., Marts, K., Mansfield, P. F., & Bodey, G. P. (1994) · Infection Control & Hospital Epidemiology · doi:10.1086/646902 · Cited by 774
Maki, D. G., Stolz, S. M., Wheeler, S., & Mermel, L. A. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-4-199708150-00001 · Cited by 753
Complications and Failures of Subclavian-Vein Catheterization
Mansfield, P. F., Hohn, D. C., Fornage, B. D., Gregurich, M. A., & Ota, D. M. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412293312602 · Cited by 713
Cited by
Loubani, O. M., & Green, R. S. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.01.014 · Cited by 235
Ricard, J.-D., Salomon, L., Boyer, A., Thiery, G., Meybeck, A., Roy, C., Pasquet, B., Le Mière, E., & Dreyfuss, D. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a42c5 · Cited by 104
Metadata
- Authors
- Taylor, R. W., & Palagiri, A. V.
- Venue
- Critical Care Medicine
- Published
- 2007-05
- Volume
- 35
- Issue
- 5
- Pages
- 1390-1396
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2014859238
- Cited by
- 299
- References
- 58
- FWCI
- 28.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Central venous catheterization. https://app.cochat.ai/papers/10.1097/01.ccm.0000260241.80346.1b
- The paper
- Taylor, R. W., & Palagiri, A. V. (2007). Central venous catheterization. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000260241.80346.1b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.