The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Echocardiographic measurement of fluid responsiveness
Abstract
PURPOSE OF REVIEW: Fluid responsiveness is a relatively new concept. It enables the efficacy of volume expansion to be predicted before use, rather than assessed afterwards, thus avoiding inappropriate fluid infusion. Echocardiography is a fantastic noninvasive tool which can directly visualize the heart and assess cardiac function. Its use was long limited by the absence of accurate indices to diagnose hypovolemia and predict the effect of volume expansion. In the last few years, several French teams have used echocardiography to develop new parameters of fluid responsiveness, taking advantage of its ability to monitor cardiac function beat by beat during the respiratory cycle. RECENT FINDINGS: In mechanically ventilated patients perfectly adapted to the respirator, respiratory variations in superior and inferior vena cava diameters and in left ventricular stroke volume have been validated as parameters of fluid responsiveness. In our opinion, the collapsibility index of the superior vena cava is the most reliable of these parameters, but does require transesophageal echocardiography. SUMMARY: Echocardiography has been widely demonstrated to predict fluid responsiveness accurately. This is now a complete and noninvasive tool able to accurately determine hemodynamic status in circulatory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Sarnoff (1954) · doi:10.1161/01.cir.9.5.706 · Cited by 602
Cited by
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Brar, S. S., Aharonian, V., Mansukhani, P., Moore, N., Shen, A. Y.-J., Jorgensen, M., Dua, A., Short, L., & Kane, K. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60689-9 · Cited by 418
J. Romero-Bermejo, F., Ruiz-Bailen, M., Gil-Cebrian, J., & J. Huertos-Ranchal, M. (2011) · Current Cardiology Reviews · doi:10.2174/157340311798220494 · Cited by 287
Stawicki, S. P., Braslow, B. M., Panebianco, N. L., Kirkpatrick, J. N., Gracias, V. H., Hayden, G. E., & Dean, A. J. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.02.062 · Cited by 260
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
Metadata
- Authors
- Charron, C., Caille, V., Jardin, F., & Vieillard-Baron, A.
- Venue
- Current Opinion in Critical Care
- Published
- 2006-06
- Volume
- 12
- Issue
- 3
- Pages
- 249-254
- ISSN
- 1070-5295 (ISSN-L)
- OpenAlex
- W2026362704
- Cited by
- 167
- References
- 2
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echocardiographic measurement of fluid responsiveness. https://app.cochat.ai/papers/10.1097/01.ccx.0000224870.24324.cc
- The paper
- Charron, C., Caille, V., Jardin, F., & Vieillard-Baron, A. (2006). Echocardiographic measurement of fluid responsiveness. Current Opinion in Critical Care. https://doi.org/10.1097/01.ccx.0000224870.24324.cc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.