The DOI matches its Crossref record.
The use of a telematic connection for the follow-up of hypertensive patients improves the cardiovascular prognosis
Abstract
BACKGROUND: Inadequate blood pressure (BP) control could be due to incorrect management of hypertensives caused by the lack of interaction between general practitioners (GP) and hypertension specialists. OBJECTIVES: To test the effectiveness on BP and total cardiovascular risk (TCVR) control of an internet-based digital network connecting specialists and GPs. METHODS: We created a network among the Hypertension Clinic, Federico II University (Naples, Italy), 23 hospital-based hypertension clinics and 60 GPs from the area (CampaniaSalute Network, CS). Randomized GPs enrolled in CS could update online records of patients (n = 1979). As a control, we included 2045 patients referred to the specialist clinics by GPs from outside the network. All patients completed a 2-year follow-up. RESULTS: CS provided a larger reduction in BP [systolic/diastolic BP (SBP/DBP): 7.3 +/- 0.4/5.4 +/- 0.3 versus 4.1 +/- 0.4/3.1 +/- 0.26 mmHg, CS versus control; P < 0.001 for both] and percentage of patients with BP < 140/90 mmHg (CS versus control: baseline, 33 versus 34%, NS; end of follow-up, 51 versus 47%, chi = 13.371; P < 0.001). A European Society of Hypertension-European Society of Cardiology (ESH/ESC) TCVR score was calculated [from 1 (average) to 5 (very high TCVR)]. The CS group showed a reduction in the mean TCVR score (CS: from 3.5 +/- 0.02 to 3.2 +/- 0, P < 0.01, ANOVA; control group: 3.5 +/- 0.03 to 3.4 +/- 0.03, NS) and, accordingly, fatal and non-fatal major cardiovascular events (MACE) were less frequent (2.9 versus 4.3%; chi = 5.047, P < 0.02). CS predicts fewer MACE in multiple binary regression analysis (beta:-7.27, P < 0.008) reducing the risk for MACE compared to control [odds ratio (OR): 0.838; 95% confidence interval (CI): 0.73-0.96]. CONCLUSION: Our results support the idea that telemedicine can achieve better control of BP and TCVR.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Advances in sensor technology for arterial pulse waveform and speed detection have paved the way for the potential development of devices for cuffless measurement of BP, in the perspective of continuous, beat-by-beat monitoring.
“advances in sensor technology for arterial pulse waveform and speed detection have paved the way for the potential development of devices for cuffless measurement of BP, in the perspective of continuous, beat-by-beat monitoring [103–106]”
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- Carretero, 2000, Essential hypertension. Part I: definition and etiology, Circulation, 101, 329, 10.1161/01.CIR.101.3.329 · DOI
- Kjeldsen, 2001, World Health Organization, International Society of Hypertension. 1999 WHO/ISH hypertension guidelines –highlights and ESH update, J Hypertens, 19, 2285, 10.1097/00004872-200112000-00026 · DOI
- Whitworth, 2003, 2003 World Health Organization (WHO)/International Society of Hypertension (ISH) statement on management of hypertension, J Hypertens, 21, 1983, 10.1097/00004872-200311000-00002 · DOI
- 2003, 2003 European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension., J Hypertens, 21, 1011, 10.1097/00004872-200306000-00001 · DOI
- Wolf-Maier, 2004, Hypertension treatment and control in five European countries, Canada, and the United States, Hypertension, 43, 10, 10.1161/01.HYP.0000103630.72812.10 · DOI
- Abdoh, 2003, Accuracy of telemedicine in detecting uncontrolled hypertension and its impact on patient management, Telemed J E Health, 9, 315, 10.1089/153056203772744635 · DOI
- Moller, 2003, Accuracy of telemedical home blood pressure measurement in the diagnosis of hypertension, J Hum Hypertens, 17, 549, 10.1038/sj.jhh.1001584 · DOI
- Rogers, 2002, Telemedicine improves diagnosis of essential hypertension compared with usual care, J Telemed Telecare, 8, 344, 10.1258/135763302320939239 · DOI
- Lembo, 2001, A common variant of endothelial nitric oxide synthase (Glu298Asp) is an independent risk factor for carotid atherosclerosis, Stroke, 32, 735, 10.1161/01.STR.32.3.735 · DOI
- Trimarco, 1985, Participation of endogenous catecholamines in the regulation of left ventricular mass in progeny of hypertensive parents, Circulation, 72, 38, 10.1161/01.CIR.72.1.38 · DOI
- Julius, 2004, Outcomes in hypertensive patients at high cardiovascular risk treated with regimens based on valsartan or amlodipine: the VALUE randomised trial, Lancet, 363, 2022, 10.1016/S0140-6736(04)16451-9 · DOI
- Dahlof, 2002, Cardiovascular morbidity and mortality in the Losartan Intervention for Endpoint reduction in hypertension study (LIFE): a randomised trial against atenolol, Lancet, 359, 995, 10.1016/S0140-6736(02)08089-3 · DOI · Paper page
Cited by
Sorted by citations
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178
Metadata
- Authors
- De Luca, N., Izzo, R., Iaccarino, G., Malini, P. L., Morisco, C., Rozza, F., Iovino, G. L., Rao, M. A. E., Bodenizza, C., Lanni, F., Guerrera, L., Arcucci, O., & Trimarco, B.
- Affiliations
- Federico II University Hospital (IT)
- University of Bologna (IT)
- Istituto Neurologico Mediterraneo (IT)
- Corresponding author
- Trimarco, Bruno
- Venue
- Journal of Hypertension
- Published
- 2005-07
- Volume
- 23
- Issue
- 7
- Pages
- 1417-1423
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1986931391
- Cited by
- 80
- References
- 0
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 7 · 2020: 3 · 2019: 1 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 6 · 2013: 7 · 2012: 9
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Systems and Technology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- hypertension, telematics, general practitioners, blood pressure control, cardiovascular risk, major adverse cardiovascular events, telemedicine, specialist-general practitioner collaboration, cardiovascular prognosis, Naples, Southern Italy
- MeSH terms
- Adolescent, Adult, Aged, Analysis of Variance, Blood Pressure Determination, Cardiovascular Diseases, Family Practice, Female, Follow-Up Studies, Hospitals, Humans, Hypertension, Male, Middle Aged, Prognosis, Referral and Consultation, Risk Factors, Time Factors, Chi-Square Distribution, Logistic Models, Odds Ratio, Telemedicine, Internet
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review