Efficacy of a home blood pressure monitoring programme on therapeutic compliance in hypertension: the EAPACUM–HTA study
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the efficacy of a programme of home blood pressure measurement (HBPM) on therapeutic compliance in mild-to-moderate hypertension. DESIGN: A prospective controlled multicentre clinical trial. SETTING: Forty primary care centres in Spain, with a duration of 6 months. PATIENTS: A total of 250 patients with newly diagnosed or uncontrolled hypertension were included. INTERVENTIONS: The patients were randomly selected and distributed in two groups: (1) the control group (CG) who received standard health intervention; (2) the intervention group (IG): the patients in this group received an OMRON in their homes for a programme of HBPM. MAIN OUTCOME MEASURE: Four visits were scheduled, for the measurement of blood pressure (BP). They were provided with an electronic monitor for measuring compliance (monitoring events medication system; MEMS). Therapeutic compliance was defined as a drug consumption of 80-110%. A number of variables were calculated using the MEMS. The mean BP were calculated and the percentage of controlled patients. RESULTS: A total of 200 patients completed the study (100 in each group). Compliance was observed in 74 and 92%, respectively, in the CG and IG [95% confidence interval (CI) 63.9-84.1 and 86.7-97.3; P = 0.0001], the mean percentage compliances were 87.6 and 93.5% (95% CI 81.2-94 and 80.7-98.3; P = 0.0001), the percentages of correct days were 83.6 and 89.4%, the percentages of subjects who took the medication at the prescribed time were 79.89 and 88.06%, and the levels of therapeutic cover were 86.7 and 93.1%. The number needed to treat to avoid one case of non-compliance was 5.6 patients. The differences in the mean decreases in BP were significant for diastolic BP, with a greater decrease observed in the IG. CONCLUSIONS: An HBPM programme using electronic monitors is effective in improving compliance in arterial hypertension, measured using the MEMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effectiveness of Interventions to Improve Patient Compliance: A Meta-Analysis
Roter, D. L., Hall, J. A., Merisca, R., Nordstrom, B., Cretin, D., & Svarstad, B. (1998) · Medical Care · doi:10.1097/00005650-199808000-00004 · Cited by 995
Interventions for helping patients to follow prescriptions for medications
Haynes, R., McDonald, H., Garg, A., & Montague, P. (2002) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000011 · Cited by 911
Friedman, R. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00353-3 · Cited by 510
Schroeder, K., Fahey, T., & Ebrahim, S. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.7.722 · Cited by 416
Recall of Recommendations and Adherence to Advice Among Patients With Chronic Medical Conditions
Kravitz, R. L. (1993) · Archives of Internal Medicine · doi:10.1001/archinte.153.16.1869 · Cited by 382
Smith, S. C., Jackson, R., Pearson, T. A., Fuster, V., Yusuf, S., Faergeman, O., Wood, D. A., Alderman, M., Horgan, J., Home, P., et al. (2004) · Circulation · doi:10.1161/01.cir.0000133427.35111.67 · Cited by 376
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Llisterri Caro, J. L., Rodríguez Roca, G. C., Alonso Moreno, F. J., Banegas Banegas, J. R., González-Segura Alsina, D., Lou Arnal, S., Divisón Garrote, J. A., Sánchez Ruiz, T., Santos Rodríguez, J. A., & Barrios Alonso, V. (2008) · Medicina Clínica · doi:10.1157/13120766 · Cited by 211
Home blood pressure monitoring. Effect on use of medical services and medical care costs.
Soghikian, K., Casper, S. M., FIREMAN, B. H., Hunkeler, E. M., Hurley, L. B., Tekawa, I. S., & VOGT, T. M. (1992) · PubMed · Cited by 174
Wetzels, G. E., Nelemans, P., Schouten, J. S., & Prins, M. H. (2004) · Journal of Hypertension · doi:10.1097/00004872-200410000-00002 · Cited by 172
Llisterri Caro, J. L., Rodríguez Roca, G. C., Alonso Moreno, F. J., Lou Arnal, S., Divisón Garrote, J. A., Santos Rodríguez, J. A., Raber Béjar, A., de Castellar Sansó, R., Ruilope Urioste, L. M., & Banegas Banegas, J. R. (2004) · Medicina Clínica · doi:10.1016/s0025-7753(04)74183-4 · Cited by 170
Zarnke, K. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(96)00305-6 · Cited by 144
Home Blood Pressure Monitoring: Effect on Use of Medical Services and Medical Care Costs
Soghikian, K., Casper, S. M., Fireman, B. H., Hunkeler, E. M., Hurley, L. B., Tekawa, I. S., & Vogt, T. M. (1992) · Medical Care · doi:10.1097/00005650-199209000-00009 · Cited by 119
Helping Patients Follow Prescribed Treatment: Clinical Applications
Haynes, R. B., McDonald, H. P., & Garg, A. X. (2002) · JAMA · doi:10.1001/jama.288.22.2880 · Cited by 98
Contreras, E. M., GarcÍa, O. V., Claros, N. M., Guillén, V. G., Wichmann, M. D. L. F. V., Martínez, J. J. C., & Fernández, R. (2005) · Blood Pressure · doi:10.1080/08037050510008977 · Cited by 83
Pharmacoeconomic Consequences of Variable Patient Compliance With Prescribed Drug Regimens
Urquhart, J. (1999) · PharmacoEconomics · doi:10.2165/00019053-199915030-00002 · Cited by 71
ASHIDA, T., SUGIYAMA, T., OKUNO, S., EBIHARA, A., & FUJII, J. (2000) · Hypertension Research · doi:10.1291/hypres.23.21 · Cited by 51
Márquez Contreras, E., Casado Martínez, J. J., Celotti Gómez, B., Gascón Vivó, J., Martín de Pablos, J. L., Gil Rodríguez, R., López Molina, V., & Domínguez, R. (2000) · Atención Primaria · doi:10.1016/s0212-6567(00)78597-0 · Cited by 48
Self-citationVetter, W., Hess, L., & Brignoli, R. (2000) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000977 · Cited by 36
Martínez, S. P., Andrés, F., Llobregat, M. D. S., & Sánchez, J. M. (1998) · PubMed · Cited by 13
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Interventions for enhancing medication adherence
Nieuwlaat, R., Wilczynski, N., Navarro, T., Hobson, N., Jeffery, R., Keepanasseril, A., Agoritsas, T., Mistry, N., Iorio, A., Jack, S., et al. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000011.pub4 · Cited by 2,945
Interventions for enhancing medication adherence
Haynes, R. B., Ackloo, E., Sahota, N., McDonald, H. P., & Yao, X. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000011.pub3 · Cited by 1,244
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Tucker, K. L., Sheppard, J. P., Stevens, R., Bosworth, H. B., Bove, A., Bray, E. P., Earle, K., George, J., Godwin, M., Green, B. B., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002389 · Cited by 658
Metadata
- Authors
- Márquez-Contreras, E., Martell-Claros, N., Gil-Guillén, V., de la Figuera-Von Wichmann, M., Casado-Martínez, J. J., Martin-de Pablos, J. L., Figueras, M., Galera, J., & Serra, A.
- Venue
- Journal of Hypertension
- Published
- 2006-01
- Volume
- 24
- Issue
- 1
- Pages
- 169-175
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2053738735
- Cited by
- 160
- References
- 20
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.