Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 510

The DOI matches its Crossref record.

A Telecommunications System for Monitoring and Counseling Patients With Hypertension Impact on Medication Adherence and Blood Pressure Control

Open access
Friedman, R·1996·American Journal of Hypertension

Abstract

This study was conducted to evaluate the effect of automated telephone patient monitoring and counseling on patient adherence to antihypertensive medications and on blood pressure control. A randomized controlled trial was conducted in 29 greater Boston communities. The study subjects were 267 patients recruited from community sites who were >or= 60 years of age, on antihypertensive medication, with a systolic blood pressure (SBP) of >or= 160 mm Hg and/or a diastolic blood pressure (DBP) of >or= 90 mm Hg. The study compared subjects who received usual medical care with those who used a computer-controlled telephone system in addition to their usual medical care during a period of 6 months. Weekly, subjects in the telephone group reported self-measured blood pressures, knowledge and adherence to antihypertensive medication regimens, and medication side-effects. This information was sent to their physicians regularly. The main study outcome measures were change in antihypertensive medication adherence, SBP and DBP during 6 months, satisfaction of patient users, perceived utility for physicians, and cost-effectiveness. The mean age of the study population was 76.0 years; 77% were women; 11% were black. Mean antihypertensive medication adherence improved 17.7% for telephone system users and 11.7% for controls (P = .03). Mean DBP decreased 5.2 mm Hg in users compared to 0.8 mm Hg in controls (P = .02). Among nonadherent subjects, mean DBP decreased 6.0 mm Hg for telephone users, but increased 2.8 mm Hg for controls (P = .01). For telephone system users, mean DBP decreased more if their medication adherence improved (P = .03). The majority of telephone system users were satisfied with the system. Most physicians integrated it into their practices. The system was cost-effective, especially for nonadherent patient users. Therefore, weekly use of an automated telephone system improved medication adherence and blood pressure control in hypertension patients. This system can be used to monitor patients with hypertension or with other chronic diseases, and is likely to improve health outcomes and reduce health services utilization and costs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0895-7061(95)00353-3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 510

Metadata

Authors
Friedman, R.
Venue
American Journal of Hypertension
Published
1996-04
Volume
9
Issue
4
Pages
285-292
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2021633655
Cited by
510
References
0
FWCI
7.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Telecommunications System for Monitoring and Counseling Patients With Hypertension Impact on Medication Adherence and Blood Pressure Control. https://app.cochat.ai/papers/10.1016/0895-7061(95)00353-3
The paper
Friedman, R. (1996). A Telecommunications System for Monitoring and Counseling Patients With Hypertension Impact on Medication Adherence and Blood Pressure Control. American Journal of Hypertension. https://doi.org/10.1016/0895-7061(95)00353-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.