Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A REANALYSIS OF ATOMIC-BOMB CATARACT DATA, 2000???2002: A THRESHOLD ANALYSIS

Nakashima, Eiji, Neriishi, Kazuo, Minamoto, Atsushi·2006·Health Physics

Abstract

To obtain the best statistical model for a previous study of cataract prevalence in atomic-bomb survivors, we tested the fitness of the threshold model in an updated dataset of the study, utilizing re-diagnosis by a single ophthalmologist, use of the DS02 dosimetry system, and separation of the in utero group. The results suggest that, in 730 atomic-bomb survivors, we cannot conclude thresholds are greater than 0 Sv in cortical cataract and posterior sub-capsular opacity since the lower 90% confidence limits of the thresholds were 0 Sv. Threshold dose point estimates were 0.6 Sv (90% CI, <0.0-1.2 Sv) and 0.7 Sv (90% CI, <0.0-2.8 Sv) for cortical cataract and posterior sub-capsular opacity, respectively. Detailed regression analyses with no threshold model showed that nuclear color and nuclear opacity have no dose responses (p > 0.40). Cortical cataract showed a significant dose effect (p = 0.002), with an odds ratio (OR)/Sv of 1.30 (95% CI, 1.10-1.53) and no dose-effect modifiers. Posterior sub-capsular opacity showed a significant dose effect (p < 0.001), with an OR/Sv of 1.44 at age of exposure of 10 y (95% CI, 1.19-1.73). The dose effect decreased significantly with increasing age at exposure (p = 0.022). No dose response was observed for in utero survivors (p > 0.20).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.hp.0000175442.03596.63

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 233

Metadata

Authors
Nakashima, E., Neriishi, K., & Minamoto, A.
Venue
Health Physics
Published
2006-02
Volume
90
Issue
2
Pages
154-160
ISSN
0017-9078 (ISSN-L)
OpenAlex
W1987286733
Cited by
233
References
2
FWCI
3.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A REANALYSIS OF ATOMIC-BOMB CATARACT DATA, 2000???2002: A THRESHOLD ANALYSIS. https://app.cochat.ai/papers/10.1097/01.hp.0000175442.03596.63
The paper
Nakashima, E., Neriishi, K., & Minamoto, A. (2006). A REANALYSIS OF ATOMIC-BOMB CATARACT DATA, 2000???2002: A THRESHOLD ANALYSIS. Health Physics. https://doi.org/10.1097/01.hp.0000175442.03596.63

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.