Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record.

Natural History of Plasma Leakage in Dengue Hemorrhagic Fever: A Serial Ultrasonographic Study

Srikiatkhachorn, Anon, Krautrachue, Anchalee, Ratanaprakarn, Warangkana, Wongtapradit, Lawan, Nithipanya, Narong, Kalayanarooj, Siripen, Nisalak, Ananda, Thomas, Stephen J., Gibbons, Robert V., Mammen, Mammen P., Libraty, Daniel H., Ennis, Francis A., Rothman, Alan L., Green, Sharone · 2007 · Pediatric Infectious Disease Journal

Abstract

BACKGROUND: Although plasma leakage is the major cause of mortality and morbidity in patients with dengue hemorrhagic fever (DHF), a detailed assessment of the natural course of this process is still lacking. We employed serial ultrasound examination to delineate the locations and the timing of plasma leakage and to evaluate the usefulness of ultrasound in detecting plasma leakage in DHF. METHOD: Daily ultrasound examinations of the abdomen and right thorax were performed in 158 suspected dengue cases to detect ascites, thickened gall bladder wall and pleural effusions. Cases were classified into dengue fever (DF), DHF or other febrile illness (OFI) based on serology and evidence of plasma leakage including hemoconcentration and pleural effusion detected by chest radiograph. RESULTS: Ultrasonographic evidence of plasma leakage was detected in DHF cases starting from 2 days before defervescence and was detected in some cases within 3 days after fever onset. Pleural effusion was the most common ultrasonographic sign of plasma leakage (62% of DHF cases one day after defervescence). Thickening of the gallbladder wall and ascites were detected less frequently (43% and 52% of DHF cases respectively) and resolved more rapidly than pleural effusions. The size of pleural effusions, ascites and gall bladder wall thickness in DHF grade I and II were smaller than those of grade III patients. Ultrasound detected plasma leakage in 12 of 17 DHF cases who did not meet the criteria for significant hemoconcentration. CONCLUSIONS: Ultrasound examinations detected plasma leakage in multiple body compartments around the time of defervescence. Ultrasonographic signs of plasma leakage were detectable before changes in hematocrits. Ultrasound is a useful tool for detecting plasma leakage in dengue infection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.inf.0000258612.26743.10

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Srikiatkhachorn, A., Krautrachue, A., Ratanaprakarn, W., Wongtapradit, L., Nithipanya, N., Kalayanarooj, S., Nisalak, A., Thomas, S. J., Gibbons, R. V., Mammen, M. P., Libraty, D. H., Ennis, F. A., Rothman, A. L., & Green, S.
Venue
Pediatric Infectious Disease Journal
Published
2007-04
Volume
26
Issue
4
Pages
283-290
ISSN
0891-3668 (ISSN-L)
OpenAlex
W2162269992
Cited by
180
References
0
FWCI
7.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Natural History of Plasma Leakage in Dengue Hemorrhagic Fever: A Serial Ultrasonographic Study. https://app.cochat.ai/papers/10.1097/01.inf.0000258612.26743.10
The paper
Srikiatkhachorn, A., Krautrachue, A., Ratanaprakarn, W., Wongtapradit, L., Nithipanya, N., Kalayanarooj, S., Nisalak, A., Thomas, S. J., Gibbons, R. V., Mammen, M. P., Libraty, D. H., Ennis, F. A., Rothman, A. L., & Green, S. (2007). Natural History of Plasma Leakage in Dengue Hemorrhagic Fever: A Serial Ultrasonographic Study. Pediatric Infectious Disease Journal. https://doi.org/10.1097/01.inf.0000258612.26743.10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.