The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Hexyl Aminolevulinate Fluorescence Cystoscopy: A New Diagnostic Tool for Photodiagnosis of Superficial Bladder Cancer—A multicenter study
Open accessAbstract
PURPOSE: We examined the sensitivity and specificity of Hexvix (PhotoCure ASA, Oslo, Norway) hexyl aminolevulinate (HAL) fluorescence cystoscopy in patients with superficial bladder cancer. MATERIALS AND METHODS: A total of 52 patients (38 men and 14 women) with a mean age of 72 years were investigated. HAL hydrochloride (100 mg dissolved in 50 ml phosphate buffer solution) (8 mM) was instilled into the bladder 1 hour prior to the endoscopic procedure. Cystoscopy was performed with the Storz D-light (Karl Storz, Tuttlingen, Germany) system, allowing inspection of the bladder wall under white and blue light (380 to 450 nm). RESULTS: A total of 422 biopsies obtained in fluorescing (165) and nonfluorescing (257) areas, including 5 random biopsies per patient, were analyzed to provide the best reference for the calculation of sensitivity and specificity. There were a total of 143 histologically verified tumors in 45 patients, including carcinoma in situ (CIS), Ta or T1 lesions. A total of 43 patients were diagnosed by fluorescence cystoscopy compared with 33 diagnosed by white light for 96% and 73% per-patient sensitivity, respectively. HAL cystoscopy was found particularly useful for finding CIS tumors. Of 13 patients with CIS tumors all except 1 were diagnosed or confirmed by HAL cystoscopy. HAL cystoscopy was well tolerated with no definite drug related adverse events reported, including effects on standard blood parameters. CONCLUSIONS: HAL fluorescence cystoscopy is a new, sensitive, promising diagnostic procedure that showed improved detection of bladder tumors, in particular CIS. The procedure is well tolerated and can easily be implemented in current clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
TNM Classification of Malignant Tumours
(1987) · Springer eBooks · doi:10.1007/978-3-642-82982-6 · Cited by 16,049
Landis, S. H., Murray, T., Bolden, S., & Wingo, P. A. (1999) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.49.1.8 · Cited by 3,068
Estimates of cancer incidence and mortality in Europe in 1995
Bray, F., Sankila, R., Ferlay, J., & Parkin, D. M. (2002) · European Journal of Cancer · doi:10.1016/s0959-8049(01)00350-1 · Cited by 686
Detection of Early Bladder Cancer by 5-Aminolevulinic Acid Induced Porphyrin Fluorescence
Kriegmair, M., Baumgartner, R., Knuchel, R., Stepp, H., Hofstadter, F., & Hofstetter, A. (1996) · Journal of Urology · doi:10.1016/s0022-5347(01)66559-5 · Cited by 434
Lange, N., Jichlinski, P., Zellweger, M., Forrer, M., Marti, A., Guillou, L., Kucera, P., Wagnières, G., & Bergh, H. V. D. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690338 · Cited by 236
Self-citationKloek, J., Akkermans, W., & van Henegouwen, G. M. J. B. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05178.x · Cited by 177
Filbeck, T., Pichlmeier, U., Knuechel, R., Wieland, W. F., & Roessler, W. (2002) · Journal of Urology · doi:10.1016/s0022-5347(05)64833-1 · Cited by 162
RIEDL, C. R., Daniltchenko, D. I., Koenig, F., Simak, R., Loening, S. A., & Pflueger, H. (2001) · The Journal of Urology · doi:10.1016/s0022-5347(05)66442-7 · Cited by 155
Kriegmair, M., Zaak, D., Rothenberger, K.-H., Rassweiler, J. J., Jocham, D., EISENBERGER, F., Tauber, R., Stenzl, A., & Hofstetter, A. G. (2002) · The Journal of Urology · doi:10.1016/s0022-5347(05)64661-7 · Cited by 130
Self-citationJichlinski, P., Forrer, M., Mizeret, J. C., Glanzmann, T. M., Braichotte, D. R., Wagnières, G., Zimmer, G., Guillou, L., Schmidlin, F. R., Graber, P., et al. (1997) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1997)20:4<402::aid-lsm5>3.0.co;2-u · Cited by 130
Self-citation
Cited by
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Nagaya, T., Nakamura, Y. A., Choyke, P. L., & Kobayashi, H. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00314 · Cited by 398
Stenzl, A., Burger, M., Fradet, Y., Mynderse, L. A., Soloway, M. S., Witjes, J. A., Kriegmair, M., Karl, A., Shen, Y., & Grossman, H. B. (2010) · Journal of Urology · doi:10.1016/j.juro.2010.06.148 · Cited by 304
Grossman, H. B., Gomella, L., Fradet, Y., Morales, A., Presti, J., Ritenour, C., Nseyo, U., Droller, M. J., & PC B302/01 Study Group (2007) · Journal of Urology · doi:10.1016/j.juro.2007.03.034 · Cited by 300
Kamat, A. M., Hegarty, P. K., Gee, J. R., Clark, P. E., Svatek, R. S., Hegarty, N., Shariat, S. F., Xylinas, E., Schmitz-Dräger, B. J., Lotan, Y., et al. (2013) · European Urology · doi:10.1016/j.eururo.2012.09.057 · Cited by 263
Metadata
- Authors
- JICHLINSKI, P., GUILLOU, L., KARLSEN, S. J., MALMSTRÖM, P.-U., JOCHAM, D., BRENNHOVD, B., JOHANSSON, E., GÄRTNER, T., LANGE, N., van den BERGH, H., & LEISINGER, H.-J.
- Venue
- Journal of Urology
- Published
- 2003-07
- Volume
- 170
- Issue
- 1
- Pages
- 226-229
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2030695905
- Cited by
- 278
- References
- 13
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hexyl Aminolevulinate Fluorescence Cystoscopy: A New Diagnostic Tool for Photodiagnosis of Superficial Bladder Cancer—A multicenter study. https://app.cochat.ai/papers/10.1097/01.ju.0000060782.52358.04
- The paper
- JICHLINSKI, P., GUILLOU, L., KARLSEN, S. J., MALMSTRÖM, P.-U., JOCHAM, D., BRENNHOVD, B., JOHANSSON, E., GÄRTNER, T., LANGE, N., van den BERGH, H., & LEISINGER, H.-J. (2003). Hexyl Aminolevulinate Fluorescence Cystoscopy: A New Diagnostic Tool for Photodiagnosis of Superficial Bladder Cancer—A multicenter study. Journal of Urology. https://doi.org/10.1097/01.ju.0000060782.52358.04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.