Conservation of Residual Acoustic Hearing After Cochlear Implantation
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: This study was designed to test the hypothesis that partial hearing conservation is attainable after cochlear implantation with a long perimodiolar electrode. Surgical strategies for hearing conservation during cochlear implantation are described. STUDY DESIGN: Prospective, single-subject, repeated-measures design. SETTING: Academic tertiary care center. PATIENTS: Twenty-eight severely to profoundly hearing-impaired adult cochlear implant recipients who had some measurable hearing preoperatively. INTERVENTION: Cochlear implantation using Nucleus Freedom Contour Advance electrode. MAIN OUTCOME MEASURES: Preimplant and postimplant pure-tone thresholds and speech recognition scores were obtained to determine the incidence and degree of conserved hearing at a mean interval of 9 (+/-3.9) months. RESULTS: Thirty-two percent of subjects experienced complete conservation of hearing (0- to 10-dB loss), and 57% experienced partial conservation of hearing (>11 dB) after implantation. However, open-set speech recognition was partially conserved in only one subject. Cochlear implant performance was not better in patients with conservation of residual hearing. CONCLUSION: Conservation of pure-tone hearing was possible in 89% of implanted patients; however, residual speech perception was not conserved with this long perimodiolar electrode. A ceiling effect tends to inflate the prevalence of hearing conservation in implantation studies of severely to profoundly hearing-impaired patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502 · cited 2×
“Furthermore, we were unable to conserve residual speech perception with a fullsize electrode, although we have been able to conserve it with the much smaller hybrid electrode (11).”
BackgroundConservation of low-frequency hearing in cochlear implantation
Kiefer, J., Gstoettner, W. K., Baumgartner, W., Pok, S. M., Tillein, J., Ye, Q., & Ilberg, C. V. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480310000755a · Cited by 309 · cited 1×
“Analysis of data to minimize the ceiling effect has been accomplished in two ways in the literature: by analyzing individual subject data (9) and by analyzing grouped data (10).”
MethodHearing preservation in cochlear implantation for electric acoustic stimulation
Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016432 · Cited by 277 · cited 1×
“(8) evaluated 21 patients after implantation with Med El Combi 40+ CI using a hearing conservation surgical technique.”
MethodComparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs
Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003) · The Laryngoscope · doi:10.1097/00005537-200303000-00005 · Cited by 257
Self-citationThorne, M., Salt, A. N., DeMott, J. E., Henson, M. M., Henson, O. W., & Gewalt, S. L. (1999) · The Laryngoscope · doi:10.1097/00005537-199910000-00021 · Cited by 254
Adunka, O., Unkelbach, M. H., MacK, M., Hambek, M., Gstoettner, W., & Kiefer, J. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410018179 · Cited by 228
Preservation of Basal Inner Ear Structures in Cochlear Implantation
Adunka, O. F., Gstoettner, W., Hambek, M., et al. (2004) · ORL · doi:10.1159/000081887 · Cited by 100
Cited by
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“The development has been both rapid and remarkable (Fraysse et al., 2006, Gantz et al., 2005, Gstoettner et al., 2008, Balkany et al., 2006 and Eshraghi et al., 2009).”
BackgroundTowards a consensus on a hearing preservation classification system
Skarzynski, H., van de Heyning, P., Agrawal, S., Arauz, S. L., Atlas, M., Baumgartner, W., Caversaccio, M., de Bodt, M., Gavilan, J., Godey, B., et al. (2013) · Acta Oto-Laryngologica · doi:10.3109/00016489.2013.869059 · Cited by 226
“[13,20] use 125 Hz whereas [14,19] do not.”
BackgroundMethodResult
Metadata
- Authors
- Balkany, T. J., Connell, S. S., Hodges, A. V., Payne, S. L., Telischi, F. F., Eshraghi, A. A., Angeli, S. I., Germani, R., Messiah, S., & Arheart, K. L.
- Venue
- Otology & Neurotology
- Published
- 2006-12
- Volume
- 27
- Issue
- 8
- Pages
- 1083-1088
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W2058229310
- Cited by
- 176
- References
- 7
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.