Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 377

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Combining acoustic and electrical hearing

Gantz, Bruce J., Turner, Christopher W.·2003·The Laryngoscope

Abstract

Objectives/Hypothesis: The concept of combining electrical stimulation for high‐frequency sound with acoustic hearing for low‐frequency information was tested. In addition, whether residual hearing can be preserved when an electrode is placed into the inner ear up to 10 mm and whether place of electrical stimulation influences speech perception were tested. Study Design: A single‐subject clinical trial design was employed. Methods: Six postlingual adults with severe high‐frequency hearing impairment were recruited to participate in the study. A new six‐channel cochlear implant was designed for the clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI‐24 multichannel implant. Monosyllabic word understanding and consonant identification testing in a recorded sound‐only condition were used to assess changes in speech perception. Follow‐up was greater than 12 months. Results: Acoustic hearing was preserved in all six subjects (n = 3,6‐mm electrodes; n = 3,10‐mm electrodes). Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30% to 40% improvement in consonant recognition occurred with the 10‐mm electrode. The subjects with 10‐mm electrodes were able to understand 83% to 90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared with preoperative scores with hearing aids only. Conclusion: The human ear has the capability to integrate both acoustic and high‐frequency electrically processed speech information. Placement of a short, 10‐mm electrode does not appear to damage residual low‐frequency inner ear hair cell function, interfere with the micro mechanics of normal cochlear vibration, or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher‐frequency consonantal speech cues, and this improvement took several months to become apparent. Such a device can provide a substantial benefit in speech understanding to individuals with severe high‐frequency hearing loss, while still maintaining the benefits of the residual lower‐frequency acoustic hearing. The position of the electrode and the place of frequency information within the cochlea were shown to be important factors in the success of such a device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005537-200310000-00012

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

See all 377

Metadata

Authors
Gantz, B. J., & Turner, C. W.
Venue
The Laryngoscope
Publisher
Wiley
Published
2003-10
Volume
113
Issue
10
Pages
1726-1730
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W1968494648
Cited by
377
References
46
FWCI
7.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combining acoustic and electrical hearing. https://app.cochat.ai/papers/10.1097/00005537-200310000-00012
The paper
Gantz, B. J., & Turner, C. W. (2003). Combining acoustic and electrical hearing. The Laryngoscope. https://doi.org/10.1097/00005537-200310000-00012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.