Development of Patient-Specific Three-Dimensional Pediatric Cardiac Models
The DOI matches its Crossref record.
Abstract
The availability of algorithms to create three-dimensional (3D) models from medical images has made it possible to render and build patient-specific reconstructions of individual body parts. In the present study, this technology was used to create 3D models of pediatric hearts for use in medical device development. Digital models were created using CT datasets of pediatric hearts and commercially available 3D image processing software. Using this software, stacked CT data were viewed, and pixels representing the heart and rib cage were selected and rendered as 3D models. Stereolithography and 3D printing technology were used to create rigid and flexible physical heart models (biomodels) from the digital models. Twelve on-screen models of the thorax and cardiac structures were created from cardiac CT scans obtained from 11 patients with and without congenital heart disease (median age, 3 years; range, 2 days to 13 years). Rigid and flexible physical heart models were generated from the digital models to provide tactile and visual information. 3D models of pediatric cardiac and chest anatomy provide enhanced understanding and tactile representation of complex anatomy. Precise representation of the spatial relationships between anatomic structures is particularly useful during the development and placement of medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiac 3D Printing and its Future Directions
Vukicevic, M., Mosadegh, B., Min, J. K., & Little, S. H. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.12.001 · Cited by 535
“Recent applications of 3D-printed congenital heart models have included interventional pre-operative planning and simulations (33–38); use of sterilized models during surgical procedures for enhanced structural orientation (11,34,39,40); functional, patient-specific hemodynamic evaluations; and testing of novel proced…”
BackgroundApplications of 3D printing in cardiovascular diseases
Giannopoulos, A. A., Mitsouras, D., Yoo, S.-J., Liu, P. P., Chatzizisis, Y. S., & Rybicki, F. J. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.170 · Cited by 421
Three-Dimensional Printing and Medical Imaging: A Review of the Methods and Applications
Marro, A., Bandukwala, T., & Mak, W. (2016) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2015.07.009 · Cited by 379
Garcia, J., Yang, Z., Mongrain, R., Leask, R. L., & Lachapelle, K. (2018) · BMJ Simulation and Technology Enhanced Learning · doi:10.1136/bmjstel-2017-000234 · Cited by 347
3D printing for preoperative planning and surgical training: a review
Ganguli, A., Pagan-Diaz, G. J., Grant, L., Cvetkovic, C., Bramlet, M., Vozenilek, J., Kesavadas, T., & Bashir, R. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0301-9 · Cited by 248
“Noecker et al. (2006) fabricated rigid and flexible models of 11 patients with and without CHD, capturing the complex arch anatomy that is present in CHD cases.”
Method
Metadata
- Authors
- Noecker, A. M., Chen, J.-F., Zhou, Q., White, R. D., Kopcak, M. W., Arruda, M. J., & Duncan, B. W.
- Venue
- ASAIO Journal
- Published
- 2006-05
- Volume
- 52
- Issue
- 3
- Pages
- 349-353
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W1987099057
- Cited by
- 95
- References
- 0
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of Patient-Specific Three-Dimensional Pediatric Cardiac Models. https://app.cochat.ai/papers/10.1097/01.mat.0000217962.98619.ab
- The paper
- Noecker, A. M., Chen, J.-F., Zhou, Q., White, R. D., Kopcak, M. W., Arruda, M. J., & Duncan, B. W. (2006). Development of Patient-Specific Three-Dimensional Pediatric Cardiac Models. ASAIO Journal. https://doi.org/10.1097/01.mat.0000217962.98619.ab
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.