Progress on the development of the MediWatch ambulatory blood pressure monitor and related devices
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The MediWatch is a wrist-mounted noninvasive blood pressure monitor designed to capture the radial pulse waveform using arterial tonometry and yield blood pressure measurements when the waveform is calibrated. An early prototype of this monitor uses a pulse-sensing system with a cylindrical plunger to applanate the radial artery. This prototype was evaluated against simulated blood pressure generated by a pneumatic pressure-pulse generator. The simulation-based results show that the prototype gave accurate pressure measurements when the MediWatch waveforms were calibrated against the simulator's pressure, indicating that the pulse-sensing system was able to measure force accurately. The prototype was clinically evaluated against intra-arterial pressure on post-open heart surgery patients. The results show that, under stationary conditions, for short periods of time and when the MediWatch waveforms were calibrated against the intra-arterial pressure, the prototype gave measurements that satisfy some of the statistical criteria of the 1993 Association for the Advancement of Medical Instrumentation standard, the 1993 British Hypertension Society protocol and the 2002 European Society of Hypertension protocol. These clinical results indicate that, under the stated test conditions, the prototype was able to accurately track changes in the patients' systolic and diastolic pressures. The MediWatch is being developed into an ambulatory device that provides a macroscopic view of the patient's blood pressure through measurement at preprogrammed intervals over 24 h, as well as a microscopic view of the patient's pressure through the pulse waveform captured during each measurement cycle. The design features of the MediWatch are being adapted for other applications that require the arterial pulse waveform, calibrated beat-to-beat blood pressure or both. An improved MediWatch prototype has been developed that provides memory storage for measurement data and functions as an integral part of a Web-based system that allows measurement data to be accessed over the Internet. A pulse-wave analyser has been developed that allows the radial pulse waveform to be captured, calibrated and viewed in real time on a personal computer. A continuous noninvasive blood pressure monitoring system based on arterial tonometry is being developed for use as an alternative to the arterial line in invasive blood pressure monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Cited by
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Evaluation of blood pressure changes using vascular transit time
Foo, J. Y. A., Lim, C. S., & Wang, P. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/003 · Cited by 62
“This type of procedure may cause much discomfort to patients when an extended period of monitoring is required (Ng et al 2004).”
Background
Metadata
- Authors
- Ng, K.-G., Ting, C.-M., Yeo, J.-H., Sim, K.-W., Peh, W.-L., Chua, N.-H., Chua, N.-K., & Kwong, F.
- Venue
- Blood Pressure Monitoring
- Published
- 2004-06
- Volume
- 9
- Issue
- 3
- Pages
- 149-165
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2127751100
- Cited by
- 40
- References
- 2
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.