Convenience of ambulatory blood pressure monitoring: comparison of different devices
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Twenty-four-hour ambulatory blood pressure monitoring has emerged as an important tool supporting physicians in the diagnosis and management of arterial hypertension. Compared with office measurements and self-measurements, however, ambulatory blood pressure monitoring shows the lowest patients' acceptance. The present study compares the convenience of different monitors in order to examine whether the patients benefit from new technologies. METHODS: In a prospective randomized study, we compared the side effects of the Spacelabs 90207 with the I.E.M. Mobilograph monitor in 250 patients by means of a questionnaire that covered the following aspects: restriction in everyday activities, noise, sleep disturbance, pain and mobility. Complaints were measured by a five-point scale ranging from 'no complaints at all' to 'severe complaints'. RESULTS: In all, 205 patients returned completed surveys (101 patients of the I.E.M. group, 104 patients of the Spacelabs group), yielding an 82% final response rate. The overall mean complaint score was significantly higher in the Spacelabs group than in the I.E.M group (2.24 vs. 1.78; P<0.001). The Mobilograph revealed less discomfort in every single question and differences were significant for restrictions in everyday activities, noise, pain, disturbance of the patient's or the patient's partner's sleep and restrictions in walking. Sleep disturbance was the aspect with the highest difference in the two groups. CONCLUSION: The present work confirms that ambulatory blood pressure monitoring monitors are cumbersome to wear. Devices, however, differ in their comfort. Monitors with an improved convenience might lead to a higher patients' acceptance of this powerful diagnostic tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Cited by
Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology
Luo, H., Yang, D., Barszczyk, A., Vempala, N., Wei, J., Wu, S. J., Zheng, P. P., Fu, G., Lee, K., & Feng, Z.-P. (2019) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.119.008857 · Cited by 241
Herrera, J., Ferrebuz, A., MacGregor, E. G., & Rodriguez-Iturbe, B. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006080918 · Cited by 233
“Initially, we planned to include ambulatory 24-h BP recordings, but several patients declined to use the monitoring devices because of the perception of increased discomfort caused by their psoriasis, in addition to the recognized mobility restrictions and disturbances in the patient’s and partners’ sleep associated w…”
MethodMaifeld, A., Bartolomaeus, H., Löber, U., Avery, E. G., Steckhan, N., Markó, L., Wilck, N., Hamad, I., Šušnjar, U., Mähler, A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22097-0 · Cited by 201
Yoga in Women With Abdominal Obesity
Cramer, H., Thoms, M. S., Anheyer, D., Lauche, R., & Dobos, G. (2016) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2016.0645 · Cited by 70
Patients’ preference for ambulatory versus home blood pressure monitoring
Nasothimiou, E. G., Karpettas, N., Dafni, M. G., & Stergiou, G. S. (2014) · Journal of Human Hypertension · doi:10.1038/jhh.2013.104 · Cited by 66
Metadata
- Authors
- Westhoff, T. H., Straub-Hohenbleicher, H., Schmidt, S., Tölle, M., Zidek, W., & Giet, M. V. D.
- Venue
- Blood Pressure Monitoring
- Published
- 2005-10
- Volume
- 10
- Issue
- 5
- Pages
- 239-242
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2093506816
- Cited by
- 36
- References
- 2
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Convenience of ambulatory blood pressure monitoring: comparison of different devices. https://app.cochat.ai/papers/10.1097/01.mbp.0000172711.82287.7f
- The paper
- Westhoff, T. H., Straub-Hohenbleicher, H., Schmidt, S., Tölle, M., Zidek, W., & Giet, M. V. D. (2005). Convenience of ambulatory blood pressure monitoring: comparison of different devices. Blood Pressure Monitoring. https://doi.org/10.1097/01.mbp.0000172711.82287.7f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.