Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Background: Cuff-based blood pressure measurement lacks comfort and convenience. Here, we examined whether blood pressure can be determined in a contactless manner using a novel smartphone-based technology called transdermal optical imaging. This technology processes imperceptible facial blood flow changes from videos captured with a smartphone camera and uses advanced machine learning to determine blood pressure from the captured signal. Methods: We enrolled 1328 normotensive adults in our study. We used an advanced machine learning algorithm to create computational models that predict reference systolic, diastolic, and pulse pressure from facial blood flow data. We used 70% of our data set to train these models and 15% of our data set to test them. The remaining 15% of the sample was used to validate model performance. Results: We found that our models predicted blood pressure with a measurement bias±SD of 0.39±7.30 mm Hg for systolic pressure, −0.20±6.00 mm Hg for diastolic pressure, and 0.52±6.42 mm Hg for pulse pressure, respectively. Conclusions: Our results in normotensive adults fall within 5±8 mm Hg of reference measurements. Future work will determine whether these models meet the clinically accepted accuracy threshold of 5±8 mm Hg when tested on a full range of blood pressures according to international accuracy standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global burden of hypertension: analysis of worldwide data
Kearney, P. M., Whelton, M., Reynolds, K., Muntner, P., Whelton, P. K., & He, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17741-1 · Cited by 8,594 · cited 2×
“These 30 decorrelated eigenvectors were then input into a multilayer perceptron machine learning algorithm (SPSS, Version 24) to generate models that best predicted: (1) systolic BP, (2) diastolic BP, and (3) pulse pressure.”
General Cardiovascular Risk Profile for Use in Primary Care: The Framingham Heart Study
D’Agostino, R. B., Vasan, R. S., Pencina, M. J., Wolf, P. A., Cobain, M., Massaro, J. M., & Kannel, W. B. (2008) · Circulation · doi:10.1161/circulationaha.107.699579 · Cited by 7,491 · cited 5×
“It should be noted that to demonstrate proof-ofconcept that TOI can measure BP, our study adopted the key accuracy criteria required by the Association for the AAMI standard as a point of reference.”
InfluentialWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
The association for the advancement of medical instrumentation
(1974) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(74)90035-0 · Cited by 1,031
Principal Manifolds for Data Visualization and Dimension Reduction
Gorban, A. N., Kégl, B., Wunsch, D. C., & Zinovyev, A. Y. (2007) · Lecture notes in computational science and engineering · doi:10.1007/978-3-540-73750-6 · Cited by 479
Machine Learning from Imbalanced Data Sets 101
Provost, F. J. (2008) · Faculty Digital Archive (New York University Florence) · Cited by 378
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
(2014) · PubMed · Cited by 237
Cited by
Stergiou, G. S., Mukkamala, R., Avolio, A., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 227
“The noncontact pulse waveform acquisition is usually based on PPG, and features of PPG waveforms from multiple skin regions-of-interest including facial PTTs can be extracted [35].”
MethodEvaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
Mukkamala, R., Yavarimanesh, M., Natarajan, K., Hahn, J.-O., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17747 · Cited by 211
Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review
Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S. (2022) · Healthcare · doi:10.3390/healthcare10030547 · Cited by 188
“A couple of studies [97,100–102] monitor the BP iPPG from a camera; others used smartphone cameras [84,101].”
BackgroundCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Camera Measurement of Physiological Vital Signs
McDuff, D. (2023) · ACM Computing Surveys · doi:10.1145/3558518 · Cited by 159
Metadata
- Authors
- Luo, H., Yang, D., Barszczyk, A., Vempala, N., Wei, J., Wu, S. J., Zheng, P. P., Fu, G., Lee, K., & Feng, Z.-P.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2019-08
- Volume
- 12
- Issue
- 8
- Pages
- e008857-e008857
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2965857341
- Cited by
- 241
- References
- 21
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology. https://app.cochat.ai/papers/10.1161/circimaging.119.008857
- The paper
- Luo, H., Yang, D., Barszczyk, A., Vempala, N., Wei, J., Wu, S. J., Zheng, P. P., Fu, G., Lee, K., & Feng, Z.-P. (2019). Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.119.008857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.