Automated assessment of blood pressure using BpTRU compared with assessments by a trained technician and a clinic nurse
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine the accuracy and reproducibility of a new automated blood pressure manometer (BpTRU) relative to auscultatory blood pressure assessed by a research nurse and to that assessed by a clinic nurse. METHODS: Firefighters in a cohort study had blood pressure assessed on up to five occasions with BpTRU and by a trained research technician. Patients in an internal medicine clinic had blood pressure assessed by the clinic nurse and by BpTRU. The absolute values of blood pressure, reproducibility and effect on hypertension classification were compared with the different methods. RESULTS: The research technician readings were higher than the BpTRU readings at visit 1 (3.0/2.7 mmHg, P<0.0001) but the readings converged by visits 4-5 because of a greater reduction in the research nurse readings. The BpTRU readings had similar reproducibility and classification of hypertension as the research technician but did not exhibit terminal digit preference while the research technician readings did. The BpTRU had substantially lower readings (8/7 mmHg) and fewer hypertensive readings than those of the nurse in the internal medicine clinic. CONCLUSIONS: This preliminary study found that the BpTRU had desirable characteristics that suggest that it would be a suitable replacement for auscultatory assessment of blood pressure in clinical practice. A large confirmatory study performed in a usual clinic setting is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Quinn, R. R., Hemmelgarn, B. R., Padwal, R. S., Myers, M. G., Cloutier, L., Bolli, P., McKay, D. W., Khan, N. A., Hill, M. D., Mahon, J., et al. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70378-0 · Cited by 346
Self-citationRoerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Effect of the Site of Measurement of Waist Circumference on the Prevalence of the Metabolic Syndrome
Mason, C., & Katzmarzyk, P. T. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.02.018 · Cited by 65
Metadata
- Authors
- Campbell, N. R. C., Conradson, H. E., Kang, J., Brant, R., & Anderson, T.
- Venue
- Blood Pressure Monitoring
- Published
- 2005-10
- Volume
- 10
- Issue
- 5
- Pages
- 257-262
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W1989378175
- Cited by
- 30
- References
- 0
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated assessment of blood pressure using BpTRU compared with assessments by a trained technician and a clinic nurse. https://app.cochat.ai/papers/10.1097/01.mbp.0000173486.44648.b2
- The paper
- Campbell, N. R. C., Conradson, H. E., Kang, J., Brant, R., & Anderson, T. (2005). Automated assessment of blood pressure using BpTRU compared with assessments by a trained technician and a clinic nurse. Blood Pressure Monitoring. https://doi.org/10.1097/01.mbp.0000173486.44648.b2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.