How cochlear implants encode speech
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: This review summarizes the history of cochlear implant signal processing and provides the rationale underlying current approaches. Present strategies are explained and recent research findings are summarized. It is suggested how these results may drive future advancements in signal processing. RECENT FINDINGS: Substantial advances have been made in our understanding of the spectral and temporal cues necessary for cochlear implant recipients to perceive music, speech in noise, and interaural timing. It is clear that higher levels of both spectral and temporal resolution, as well as better loudness and pitch coding are necessary for higher levels of performance. These factors are highly interrelated, however, and are beneficial for differing aspects of hearing. Signal processing algorithms incorporating these findings are under active development and some are currently undergoing clinical investigation. SUMMARY: Current implant devices, and those soon to be available, have substantial untapped potential to improve the auditory experience of their recipients. It is likely that in the near future, recent findings on pitch and loudness perception, as well as techniques to better emulate the normal functions of the cochlea will result in much higher levels of prosthetic hearing fidelity than are possible today. As the performance of these remarkable devices continues to improve, the population of hearing-impaired individuals who can benefit from implantation is likely to increase significantly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
An Introduction to the Psychology of Hearing: Fourth Edition
Moore, B. (1997) · BRILL eBooks · doi:10.1163/9789004658820 · Cited by 2,646
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Chimaeric sounds reveal dichotomies in auditory perception
Smith, Z. M., Delgutte, B., & Oxenham, A. J. (2002) · Nature · doi:10.1038/416087a · Cited by 873
Cross-modal plasticity and cochlear implants
Lee, D. S., Lee, J. S., Oh, S. H., Kim, S.-K., Kim, J.-W., Chung, J.-K., Lee, M. C., & Kim, C. S. (2001) · Nature · doi:10.1038/35051653 · Cited by 480
Cochlear Hearing Loss: Physiological, Psychological and Technical Issues
Moore, B. C. J. (2007) · Wiley eBooks · doi:10.1002/9780470987889 · Cited by 445
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Long Term Results of Electrode Implantation and Electronic Stimulation of the Cochlea in Man
House, W. F., & Urban, J. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200408 · Cited by 354
Correct tonotopic representation is necessary for complex pitch perception
Oxenham, A. J., Bernstein, J. G. W., & Penagos, H. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0306958101 · Cited by 238
Temporal processing and speech recognition in cochlear implant users
Fu, Q.-J. (2002) · NeuroReport · doi:10.1097/00001756-200209160-00013 · Cited by 237
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“Because several review papers have been published to focus on this topic [40,54-56], this section provides a brief overall review and an update.”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Technological, biological, and acoustical constraints to music perception in cochlear implant users
Limb, C. J., & Roy, A. T. (2014) · Hearing Research · doi:10.1016/j.heares.2013.04.009 · Cited by 274
Implantable biomedical devices: Wireless powering and communication
Yakovlev, A., Kim, S., & Poon, A. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6178849 · Cited by 213
Clinical Evaluation of an Image-Guided Cochlear Implant Programming Strategy
Noble, J. H., Gifford, R. H., Hedley-Williams, A. J., Dawant, B. M., & Labadie, R. F. (2014) · Audiology and Neurotology · doi:10.1159/000365273 · Cited by 162
Metadata
- Authors
- Rubinstein, J. T.
- Venue
- Current Opinion in Otolaryngology & Head and Neck Surgery
- Published
- 2004-10
- Volume
- 12
- Issue
- 5
- Pages
- 444-448
- ISSN
- 1068-9508 (ISSN-L)
- OpenAlex
- W2023585704
- Cited by
- 209
- References
- 34
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How cochlear implants encode speech. https://app.cochat.ai/papers/10.1097/01.moo.0000134452.24819.c0
- The paper
- Rubinstein, J. T. (2004). How cochlear implants encode speech. Current Opinion in Otolaryngology & Head and Neck Surgery. https://doi.org/10.1097/01.moo.0000134452.24819.c0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.