How cochlear implants encode speech
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: This review summarizes the history of cochlear implant signal processing and provides the rationale underlying current approaches. Present strategies are explained and recent research findings are summarized. It is suggested how these results may drive future advancements in signal processing. RECENT FINDINGS: Substantial advances have been made in our understanding of the spectral and temporal cues necessary for cochlear implant recipients to perceive music, speech in noise, and interaural timing. It is clear that higher levels of both spectral and temporal resolution, as well as better loudness and pitch coding are necessary for higher levels of performance. These factors are highly interrelated, however, and are beneficial for differing aspects of hearing. Signal processing algorithms incorporating these findings are under active development and some are currently undergoing clinical investigation. SUMMARY: Current implant devices, and those soon to be available, have substantial untapped potential to improve the auditory experience of their recipients. It is likely that in the near future, recent findings on pitch and loudness perception, as well as techniques to better emulate the normal functions of the cochlea will result in much higher levels of prosthetic hearing fidelity than are possible today. As the performance of these remarkable devices continues to improve, the population of hearing-impaired individuals who can benefit from implantation is likely to increase significantly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
An Introduction to the Psychology of Hearing: Fourth Edition
Moore, B. (1997) · BRILL eBooks · doi:10.1163/9789004658820 · Cited by 2,646
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Chimaeric sounds reveal dichotomies in auditory perception
Smith, Z. M., Delgutte, B., & Oxenham, A. J. (2002) · Nature · doi:10.1038/416087a · Cited by 873
Cross-modal plasticity and cochlear implants
Lee, D. S., Lee, J. S., Oh, S. H., Kim, S.-K., Kim, J.-W., Chung, J.-K., Lee, M. C., & Kim, C. S. (2001) · Nature · doi:10.1038/35051653 · Cited by 480
Cochlear Hearing Loss: Physiological, Psychological and Technical Issues
Moore, B. C. J. (2007) · Wiley eBooks · doi:10.1002/9780470987889 · Cited by 445
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Long Term Results of Electrode Implantation and Electronic Stimulation of the Cochlea in Man
House, W. F., & Urban, J. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200408 · Cited by 354
Correct tonotopic representation is necessary for complex pitch perception
Oxenham, A. J., Bernstein, J. G. W., & Penagos, H. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0306958101 · Cited by 238
Temporal processing and speech recognition in cochlear implant users
Fu, Q.-J. (2002) · NeuroReport · doi:10.1097/00001756-200209160-00013 · Cited by 237
Cohen, L. T., Richardson, L. M., Saunders, E., & Cowan, R. S. C. (2003) · Hearing Research · doi:10.1016/s0378-5955(03)00096-0 · Cited by 220
The resolution of complex spectral patterns by cochlear implant and normal-hearing listeners
Henry, B. A., & Turner, C. W. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1561900 · Cited by 187
Speech discrimination in deaf subjects with cochlear implants
Eddington, D. K. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384827 · Cited by 186
Shepherd, R. K., & Javel, E. (1999) · Hearing Research · doi:10.1016/s0378-5955(99)00011-8 · Cited by 186
Cochlear Implants: Some Likely Next Steps
Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121645 · Cited by 160
Phase-locking of auditory-nerve discharges to sinusoidal electric stimulation of the cochlea
Dynes, S., & Delgutte, B. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90011-b · Cited by 137
Quadrupolar stimulation for cochlear prostheses: modeling and experimental data
Jolly, C. N., Spelman, F. A., & Clopton, B. M. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508549 · Cited by 132
Speech recognition under conditions of frequency-place compression and expansion
Başkent, D., & Shannon, R. V. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1558357 · Cited by 118
Adaptive Dynamic Range Optimization for Cochlear Implants: A Preliminary Study
James, C. J., Blamey, P. J., Martin, L. F. A., Swanson, B. A., Just, Y., & Macfarlane, D. S. (2002) · Ear and Hearing · doi:10.1097/00003446-200202001-00006 · Cited by 101
Litvak, L. M., Smith, Z. M., Delgutte, B., & Eddington, D. K. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1612492 · Cited by 85
Electrical field interactions in different cochlear implant systems
Boëx, C., de Balthasar, C., Kós, M.-I., & Pelizzone, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1610451 · Cited by 85
Temporal pitch mechanisms in acoustic and electric hearing
Carlyon, R. P., Wieringen, A. V., Long, C. J., Deeks, J. M., & Wouters, J. M. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1488660 · Cited by 84
Effects of Electrode-to-Fiber Distance on Temporal Neural Response With Electrical Stimulation
Mino, H., Rubinstein, J. T., Miller, C. A., & Abbas, P. J. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820383 · Cited by 80
Self-citationThe effects of short-term training for spectrally mismatched noise-band speech
Fu, Q., & Galvin, J. J. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1537708 · Cited by 78
Signal Coding in Cochlear Implants: Exploiting Stochastic Effects of Electrical Stimulation
Rubinstein, J. T., & Hong, R. (2003) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894031120s904 · Cited by 77
Self-citationLitvak, L. M., Delgutte, B., & Eddington, D. K. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1612493 · Cited by 69
Forward masking in different cochlear implant systems
Boëx, C., Kós, M.-I., & Pelizzone, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1610452 · Cited by 69
Miller, C. A., Abbas, P. J., Nourski, K. V., Hu, N., & Robinson, B. K. (2003) · Hearing Research · doi:10.1016/s0378-5955(02)00739-6 · Cited by 66
Johnson, P. E., Belafsky, P. C., & Postma, G. N. (2003) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940311200104 · Cited by 61
How do cochlear prostheses work?
Rubinstein, J. T., & Miller, C. A. (1999) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(99)80060-9 · Cited by 55
Self-citationCochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array
Hillman, T., Badi, A. N., Normann, R. A., Kertesz, T., & Shelton, C. (2003) · Otology & Neurotology · doi:10.1097/00129492-200309000-00013 · Cited by 52
Wackym, P. A., Firszt, J. B., Gaggl, W., et al. (2003) · The Laryngoscope · doi:10.1097/00005537-200401000-00012 · Cited by 48
Hong, R., & Rubinstein, J. T. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1623785 · Cited by 39
Self-citationImproved neural representation of vowels in electric stimulation using desynchronizing pulse trains
Litvak, L. M., Delgutte, B., & Eddington, D. K. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1612494 · Cited by 31
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“Because several review papers have been published to focus on this topic [40,54-56], this section provides a brief overall review and an update.”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Technological, biological, and acoustical constraints to music perception in cochlear implant users
Limb, C. J., & Roy, A. T. (2014) · Hearing Research · doi:10.1016/j.heares.2013.04.009 · Cited by 274
Implantable biomedical devices: Wireless powering and communication
Yakovlev, A., Kim, S., & Poon, A. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6178849 · Cited by 213
Speech Perception in Noise by Children With Cochlear Implants
Caldwell, A., & Nittrouer, S. (2013) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2012/11-0338 · Cited by 178
“The development of CIs as a treatment for severe to profound hearing loss has done nothing to improve this particular problem because processing strategies in these devices are designed to deliver only spectrally broad signals to the auditory system (e.g., Rubinstein, 2004).”
Background
Metadata
- Authors
- Rubinstein, J. T.
- Venue
- Current Opinion in Otolaryngology & Head and Neck Surgery
- Published
- 2004-10
- Volume
- 12
- Issue
- 5
- Pages
- 444-448
- ISSN
- 1068-9508 (ISSN-L)
- OpenAlex
- W2023585704
- Cited by
- 209
- References
- 34
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.