The Interpretation of the EEG in Stupor and Coma
The DOI matches its Crossref record.
Abstract
This review discusses a variety of causes of stupor and coma and associated electroencephalographic (EEG) findings. These include metabolic disturbances such as hepatic or renal dysfunction, which are often characterized by slowing of background rhythms and triphasic waves. Hypoxia and drug intoxications can produce a number of abnormal EEG patterns such as burst suppression, alpha coma, and spindle coma. Structural lesions, either supra- or infratentorial, are reviewed. EEGs in the former may show focal disturbances such as delta and theta activity, epileptiform abnormalities, and attenuation of faster frequencies. In infratentorial lesions, the EEG may appear normal, particularly with a pontine lesion. Some patients may be encephalopathic because of ongoing epileptic activity with minimal or no motor movements. This entity, nonconvulsive status epilepticus (NCSE), is difficult to diagnose in obtunded/comatose patients, and an EEG is required to verify the diagnosis and to monitor treatment. Several EEG patterns and their interpretation in suspected cases of NCSE such as periodic lateralized epileptiform discharges (PLEDs), bilateral independent periodic lateralized epileptiform discharges (BIPLEDs), generalized periodic epileptiform discharges (GPEDs), and triphasic waves are reviewed. Other entities discussed include the locked-in syndrome, neocortical death, persistent vegetative state, brainstem death, and brain death.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control of sleep and wakefulness
Brown, R. E., Basheer, R., McKenna, J. T., Strecker, R. E., & McCarley, R. W. (2012) · Physiological Reviews · doi:10.1152/physrev.00032.2011 · Cited by 1,477
Electroencephalogram signatures of loss and recovery of consciousness from propofol
Purdon, P. L., Pierce, E. T., Mukamel, E. A., Prerau, M. J., Walsh, J. L., Wong, K. F. K., Salazar-Gomez, A. F., Harrell, P. G., Sampson, A. L., Cimenser, A., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221180110 · Cited by 854
Interpreting EEG alpha activity
Bazanova, O. M., & Vernon, D. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.05.007 · Cited by 574
Trinka, E., Höfler, J., & Zerbs, A. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03622.x · Cited by 202
“The epileptic etiology is most often confirmed only by the presence of continuous or discontinuous epileptiform discharges on the EEG (Lowenstein & Aminoff, 1992; Jordan, 1999; Brenner, 2005).”
BackgroundWatson, P. L., Pandharipande, P., Gehlbach, B. K., Thompson, J. L., Shintani, A. K., Dittus, B. S., Bernard, G. R., Malow, B. A., & Ely, E. W. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a3f75 · Cited by 166
Metadata
- Authors
- Brenner, R. P.
- Venue
- The Neurologist
- Published
- 2005-09
- Volume
- 11
- Issue
- 5
- Pages
- 271-284
- ISSN
- 1074-7931 (ISSN-L)
- OpenAlex
- W2049277090
- Cited by
- 139
- References
- 0
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Interpretation of the EEG in Stupor and Coma. https://app.cochat.ai/papers/10.1097/01.nrl.0000178756.44055.f6
- The paper
- Brenner, R. P. (2005). The Interpretation of the EEG in Stupor and Coma. The Neurologist. https://doi.org/10.1097/01.nrl.0000178756.44055.f6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.