The DOI matches its Crossref record.
Facial Skeletal Reconstruction Using Porous Polyethylene Implants
Abstract
A retrospective review of clinical outcomes was performed to determine the clinical utility and morbidity associated with the use of porous polyethylene facial implants. Three hundred seventy implants were placed in 162 consecutive patients, in 178 operations performed in 11 years. The number of patients, the number of implants used, and the average follow-up period were categorized according to the cause of the deformity. The resultant distribution was as follows: acquired (tumor-related), 17 patients, 39 implants, and 30 months; congenital, eight patients, 31 implants, and 92 months; aesthetic, 39 patients, 97 implants, and 24 months; secondary posttraumatic, 48 patients, 139 implants, and 37 months; and acute trauma (internal orbit reconstruction), 50 patients, 64 implants, and 9 months. The distribution of implants according to location was as follows: frontal, 21; temporal, 30; internal orbit, 145; infraorbital rim, 28; malar, 58; paranasal, 29; nasal, 13; mandible, 24; and chin, 22. The combined average follow-up period per patient was 27 months (range, immediate postoperative period to 11 years). All implants were placed in the subperiosteal plane, and the majority were fixed with titanium screws. Antibiotics were administered perioperatively. No implants were extruded or migrated, formed clinically apparent capsules, or caused symptoms attributable to bioincompatibility. The overall reoperation rate was 10 percent (n = 16), which included operations to remove implants because of acute infections (2 percent, n = 3) or a late infection (1 percent, n = 1), to remove implants causing displeasing contours (2 percent, n = 3), and to improve contours (6 percent, n = 9). Porous polyethylene implants have biomaterial properties favorable for facial skeletal augmentation. Screw application of the implants to the skeleton allows precise predictable contouring, thus limiting the need for revisional surgical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Injectable Biomaterials for Regenerating Complex Craniofacial Tissues
Kretlow, J. D., Young, S., Klouda, L., Wong, M., & Mikos, A. G. (2009) · Advanced Materials · doi:10.1002/adma.200802009 · Cited by 302
Aging of the Facial Skeleton: Aesthetic Implications and Rejuvenation Strategies
Shaw, R. B., Katzel, E. B., Koltz, P. F., Yaremchuk, M. J., Girotto, J. A., Kahn, D. M., & Langstein, H. N. (2011) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181f95b2d · Cited by 264
Self-citationCraniofacial reconstruction with high-density porous polyethylene implants.
Menderes, A., Baytekin, C., Topcu, A., Yilmaz, M., & Barutcu, A. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200409000-00004 · Cited by 90
The Use of High-Density Porous Polyethylene as a Custom-Made Nasal Spreader Graft
Gürlek, A., Celik, M., Fariz, A., Ersöz-Öztürk, A., Eren, A. T., & Tenekeci, G. (2006) · Aesthetic Plastic Surgery · doi:10.1007/s00266-005-0119-8 · Cited by 47
Metadata
- Authors
- Yaremchuk, M. J.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2003-05
- Volume
- 111
- Issue
- 6
- Pages
- 1818-1827
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1991276669
- Cited by
- 226
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Facial Skeletal Reconstruction Using Porous Polyethylene Implants. https://app.cochat.ai/papers/10.1097/01.prs.0000056866.80665.7a
- The paper
- Yaremchuk, M. J. (2003). Facial Skeletal Reconstruction Using Porous Polyethylene Implants. Plastic and Reconstructive Surgery. https://doi.org/10.1097/01.prs.0000056866.80665.7a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.