Abstract
For the reconstructive surgeon, tissue-engineered skeletal muscle may offer reduced donor-site morbidity and an unlimited supply of tissue. Using an acellularized mouse extensor digitorum longus muscle as a scaffold, the authors produced engineered skeletal muscle capable of generating longitudinal force. Eight extensor digitorum longus muscles from adult mice were made acellular using a protocol developed in the authors' laboratory. The acellular muscles were then placed in a bath of 20% fetal bovine serum in Dulbecco's modified Eagle's medium and 100 U/ml penicillin for 1 week at room temperature. C2C12 myoblasts were injected into the acellular muscle matrix using a 26-gauge needle and a 100-microl syringe. The resulting constructs were placed in growth medium for 1 week at 37 degrees C under 5% carbon dioxide, with media changes every 48 hours. The constructs were then placed in differentiation medium for 1 week, with media changes every 48 hours. Isometric contractile force testing of the constructs demonstrated production of longitudinal contractile force on electrical stimulation. A length-tension, or Starling, relationship was observed. Light and electron microscopy studies demonstrated recapitulation of some of the normal histologic features of developing skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An overview of tissue and whole organ decellularization processes
Crapo, P. M., Gilbert, T. W., & Badylak, S. F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.057 · Cited by 3,591
Decellularization of tissues and organs
Gilbert, T. W., Sellaro, T. L., & Badylak, S. F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.014 · Cited by 2,222
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
“Recent efforts with muscle tissue constructs for implantation probably fit the latter description (Borschel et al., 2004).”
BackgroundReprint of: Extracellular matrix as a biological scaffold material: Structure and function
Badylak, S. F., Freytes, D. O., & Gilbert, T. W. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.016 · Cited by 1,362
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Metadata
- Authors
- Borschel, G. H., Dennis, R. G., & Kuzon, W. M.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2004-02
- Volume
- 113
- Issue
- 2
- Pages
- 595-602
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2059366516
- Cited by
- 153
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contractile Skeletal Muscle Tissue-Engineered on an Acellular Scaffold. https://app.cochat.ai/papers/10.1097/01.prs.0000101064.62289.2f
- The paper
- Borschel, G. H., Dennis, R. G., & Kuzon, W. M. (2004). Contractile Skeletal Muscle Tissue-Engineered on an Acellular Scaffold. Plastic and Reconstructive Surgery. https://doi.org/10.1097/01.prs.0000101064.62289.2f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.