CoChat

Silsesquioxane Nanocomposites as Tissue Implants

Kannan, Ruben Y., Salacinski, Henryk J., Ghanavi, Jalal-edin, Narula, Ashish, Odlyha, Marianne, Peirovi, Habiballah, Butler, Peter E., Seifalian, Alexander M. · 2007 · Plastic and Reconstructive Surgery
Cited by 99

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Silicone implants are being used increasingly worldwide, especially in breast augmentation procedures. The most common morbidity observed is capsular contracture, which occurs in 15 percent of cases. To overcome this problem, the authors have developed a novel nanocomposite based on polyhedral oligomeric silsesquioxane-poly(carbonate-urea)urethane (POSS-PCU) for use as tissue implants. METHODS: These polymers were implanted in six healthy sheep (n = 6) for 36 months and a siloxane served as the positive control. After explantation, these polymers were extracted, as was the surrounding capsule, if any. Attenuated total reflectance Fourier transform infrared spectroscopy analysis was performed to look for signs of surface degradation on the polymers and histopathologic and electron microscopic examinations were performed to study the interaction between the biomaterial and the host environment in greater detail. RESULTS: After implantation, the authors observed minimal inflammation of the nanocomposite within the sheep model as compared with the siloxane control. Contact angle measurements and fibrinogen enzyme-linked immunosorbent assay tests were then conducted on the POSS-PCU nanocomposite to determine the reason for this behavior. The increased fibrinogen adsorption on POSS-PCU, its amphilicity, and large contact-angle hysteresis indicated that POSS-PCU inhibits inflammation by adsorbing and inactivating fibrinogen on its surface. In complete contrast, the control siloxane in the same setting demonstrated very significant inflammation and degradation, resulting in capsular formation. Naturally, there was no evidence of degradation of the nanocomposite compared with the siloxane control. CONCLUSIONS: POSS-PCU nanocomposites have enhanced interfacial biocompatibility and better biological stability as compared with conventional silicone biomaterials, thus making them safer as tissue implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.prs.0000246404.53831.4c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 99

Metadata

Authors
Kannan, R. Y., Salacinski, H. J., Ghanavi, J.-E., Narula, A., Odlyha, M., Peirovi, H., Butler, P. E., & Seifalian, A. M.
Venue
Plastic and Reconstructive Surgery
Published
2007-05
Volume
119
Issue
6
Pages
1653-1662
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2060872636
Cited by
99
References
2
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Silsesquioxane Nanocomposites as Tissue Implants. https://app.cochat.ai/papers/10.1097/01.prs.0000246404.53831.4c
The paper
Kannan, R. Y., Salacinski, H. J., Ghanavi, J.-E., Narula, A., Odlyha, M., Peirovi, H., Butler, P. E., & Seifalian, A. M. (2007). Silsesquioxane Nanocomposites as Tissue Implants. Plastic and Reconstructive Surgery. https://doi.org/10.1097/01.prs.0000246404.53831.4c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.