The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Clinical and Morphological Conditions in Capsular Contracture Formed around Silicone Breast Implants
Abstract
BACKGROUND: A study was performed to investigate histological changes in capsules formed around silicone breast implants and their correlation with the clinical classification of capsular contracture defined by the Baker score. For histological classification, the authors used the classification introduced by Wilflingseder, which identifies four grades of contracture. METHODS: The study included 24 female patients (average age, 40 +/- 12 years) with capsular contracture after bilateral cosmetic breast augmentation with smooth silicone gel implants (Mentor, Santa Barbara, Calif.). The Baker score was determined preoperatively for each patient. Samples of capsular tissue were obtained from all patients for histologic and immunohistochemical analyses. Capsular thickness, age of the collagen fibers, presence of synovia-like metaplasia on the inner surface of the capsule, number of histiocytes, giant cells, and other inflammatory cells, amount of silicone, foreign body granulomas, and capsule calcification were evaluated. RESULTS: There was a positive correlation between capsular thickness (p < 0.05) and Baker score. Silicone-containing deposits were found in all four histological capsule types. A trend toward greater capsular thickness was documented in patients with severe inflammatory reaction. These patients also had more clinical symptoms. Greater capsular thickness was associated with a higher number of silicone particles and silicone-loaded macrophages in the peri-implant capsule. CONCLUSIONS: The authors demonstrated a positive correlation (p < 0.05) between the clinical classification (Baker score I to IV) and the histological classification introduced by Wilflingseder (Wilflingseder score I to IV). An exact histological classification is needed to describe precisely the morphological changes in capsular contracture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
TGF-β signaling and the fibrotic response
Leask, A., & Abraham, D. J. (2004) · The FASEB Journal · doi:10.1096/fj.03-1273rev · Cited by 2,319
Human monocyte/macrophage activation and interleukin 1 generation by biomedical polymers
Miller, K. M., & Anderson, J. M. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220805 · Cited by 156
Intercostal Neuromas: A Treatable Cause of Postoperative Breast Surgery Pain
Wong, L. (2001) · Annals of Plastic Surgery · doi:10.1097/00000637-200105000-00004 · Cited by 67
Cited by
Immunomodulatory Biomaterials for Tissue Repair
Whitaker, R., Hernaez-Estrada, B., Hernandez, R. M., Santos-Vizcaino, E., & Spiller, K. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00895 · Cited by 338
Metadata
- Authors
- Prantl, L., Schreml, S., Fichtner-Feigl, S., P??ppl, N., Eisenmann-Klein, M., Schwarze, H., & F??chtmeier, B.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2007-07
- Volume
- 120
- Issue
- 1
- Pages
- 275-284
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2094903240
- Cited by
- 200
- References
- 3
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical and Morphological Conditions in Capsular Contracture Formed around Silicone Breast Implants. https://app.cochat.ai/papers/10.1097/01.prs.0000264398.85652.9a
- The paper
- Prantl, L., Schreml, S., Fichtner-Feigl, S., P??ppl, N., Eisenmann-Klein, M., Schwarze, H., & F??chtmeier, B. (2007). Clinical and Morphological Conditions in Capsular Contracture Formed around Silicone Breast Implants. Plastic and Reconstructive Surgery. https://doi.org/10.1097/01.prs.0000264398.85652.9a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.