Cited by 156Polymer Surface Interaction StudiesOrthopaedic implants and arthroplastyImmune Response and Inflammation

Human monocyte/macrophage activation and interleukin 1 generation by biomedical polymers

Miller, K. M., Anderson, J. M.·1988·Journal of Biomedical Materials Research

Abstract

In vitro cell culture techniques were used to evaluate the effect of several clinically significant biomedical polymers on monocyte activation and Interleukin 1 (IL1) production. Isolated human peripheral blood monocytes were cultured in the presence of a panel of five biomedical polymers routinely used in a variety of clinical applications: Polyethylene (PE), silica-free poly-dimethylsiloxane (PDMS), woven Dacron fabric, expanded polytetrafluoroethylene (ePTFE) and the segmented polyurethane, Biomer. Monocytes generated IL1 in the presence of all five materials. Maximal levels of IL1 were generated at 24 h in monocyte-polymer cultures supplemented with serum and additionally stimulated with lipopolysaccharide (LPS). No difference was observed due to serum source. Results from cultures supplemented with fetal bovine serum were not significantly different from those obtained with human serum supplemented cultures. The thymocyte proliferative activity generated by monocytes in the presence of these biomedical polymers was neutralized by a specific polyclonal anti-IL1 antiserum. Statistically significant differences in IL1 production were observed between polymers, allowing their classification according to reactivity into high (Dacron, PE), intermediate (ePTFE) and low (Biomer, PDMS) reactive groups.

Integrity signals

Registry

Crossref · 10.1002/jbm.820220805

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Differential IL-1 production from macrophages cultured on biomaterials allowed assessment of the reactivity of the polymer as a measure of biocompatibility.

    “Differential IL-1 production from macrophages cultured on biomaterials allowed us to assess the reactivity of the polymer as a measure of biocompatibility.[102, 103]”

    From Foreign body reaction to biomaterials (2008) · cites this paper as [102]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Miller, K. M., & Anderson, J. M.
Affiliations
Case Western Reserve University (US)
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1988-08
Volume
22
Issue
8
Pages
713-731
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W1972227130
Cited by
156
References
1
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2022: 6 · 2021: 1 · 2020: 3 · 2018: 4 · 2017: 1 · 2016: 3 · 2014: 3 · 2013: 4 · 2012: 3
FWCI
5.94
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Heart, Lung, and Blood Institute (HL 33849)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
  • Life Sciences › Immunology and Microbiology › Immunology › Immune Response and Inflammation
Keywords
monocyte activation, interleukin-1, biomedical polymers, biocompatibility, polyethylene, polydimethylsiloxane, expanded polytetrafluoroethylene, segmented polyurethanes, Biomer, lipopolysaccharide, thymocyte proliferation
MeSH terms
Biocompatible Materials, Cells, Cultured, Humans, Interleukin-1, Kinetics, Lymphocyte Activation, Macrophage Activation, Macrophages, Monocytes, Polymers, T-Lymphocytes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review