Human monocyte/macrophage activation and interleukin 1 generation by biomedical polymers
Abstract
In vitro cell culture techniques were used to evaluate the effect of several clinically significant biomedical polymers on monocyte activation and Interleukin 1 (IL1) production. Isolated human peripheral blood monocytes were cultured in the presence of a panel of five biomedical polymers routinely used in a variety of clinical applications: Polyethylene (PE), silica-free poly-dimethylsiloxane (PDMS), woven Dacron fabric, expanded polytetrafluoroethylene (ePTFE) and the segmented polyurethane, Biomer. Monocytes generated IL1 in the presence of all five materials. Maximal levels of IL1 were generated at 24 h in monocyte-polymer cultures supplemented with serum and additionally stimulated with lipopolysaccharide (LPS). No difference was observed due to serum source. Results from cultures supplemented with fetal bovine serum were not significantly different from those obtained with human serum supplemented cultures. The thymocyte proliferative activity generated by monocytes in the presence of these biomedical polymers was neutralized by a specific polyclonal anti-IL1 antiserum. Statistically significant differences in IL1 production were observed between polymers, allowing their classification according to reactivity into high (Dacron, PE), intermediate (ePTFE) and low (Biomer, PDMS) reactive groups.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Differential IL-1 production from macrophages cultured on biomaterials allowed assessment of the reactivity of the polymer as a measure of biocompatibility.
“Differential IL-1 production from macrophages cultured on biomaterials allowed us to assess the reactivity of the polymer as a measure of biocompatibility.[102, 103]”
From Foreign body reaction to biomaterials (2008) · cites this paper as [102]
Cites
Secretory products of macrophages.
Nathan, C. F. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112815 · Cited by 2,615 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · see citing works
Self-citationBélanger, M., & Marois, Y. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1043 · Cited by 471 · see citing works
Jones, J. A., Chang, D. T., Meyerson, H., Colton, E., Kwon, I. K., Matsuda, T., & Anderson, J. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31221 · Cited by 352 · see citing works
Self-citationIn vitro models of biocompatibility: A review
Hanks, C. T., Wataha, J. C., & Sun, Z. (1996) · Dental Materials · doi:10.1016/s0109-5641(96)80020-0 · Cited by 283 · see citing works
Bota, P. C. S., Collie, A. M. B., Puolakkainen, P., Vernon, R. B., Sage, E. H., Ratner, B. D., & Stayton, P. S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32893 · Cited by 186 · see citing works
Current trends in biocompatibility testing
Kirkpatrick, C. J., Bittinger, F., Wagner, M., Köhler, H., van Kooten, T. G., Klein, C. L., & Otto, M. (1998) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411981533845 · Cited by 145 · see citing works
Cytokine and growth factor production by monocytes/macrophages on protein preadsorbed polymers
Bonfield, T. L., Colton, E., Marchant, R. E., & Anderson, J. M. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260702 · Cited by 119 · see citing works
Self-citationMiller, K. M., Rose‐Caprara, V., & Anderson, J. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230904 · Cited by 84 · see citing works
Self-citationMiller, K. M., & Anderson, J. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230808 · Cited by 82 · see citing works
Self-citationEnhanced Biocompatibility in Biostable Poly(carbonate)urethane
Hsu, S., Kao, Y., & Lin, Z. (2004) · Macromolecular Bioscience · doi:10.1002/mabi.200300082 · Cited by 33 · see citing works
- Authors
- Miller, K. M., & Anderson, J. M.
- Affiliations
- Case Western Reserve University (US)
- ORCID
- Miller, K. M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1988-08
- Volume
- 22
- Issue
- 8
- Pages
- 713-731
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1972227130
- Cited by
- 156
- References
- 1
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 6 · 2021: 1 · 2020: 3 · 2018: 4 · 2017: 1 · 2016: 3 · 2014: 3 · 2013: 4 · 2012: 3
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL 33849)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Life Sciences › Immunology and Microbiology › Immunology › Immune Response and Inflammation
- Keywords
- monocyte activation, interleukin-1, biomedical polymers, biocompatibility, polyethylene, polydimethylsiloxane, expanded polytetrafluoroethylene, segmented polyurethanes, Biomer, lipopolysaccharide, thymocyte proliferation
- MeSH terms
- Biocompatible Materials, Cells, Cultured, Humans, Interleukin-1, Kinetics, Lymphocyte Activation, Macrophage Activation, Macrophages, Monocytes, Polymers, T-Lymphocytes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review