CoChat

Automated Quantification of Body Fat Distribution on Volumetric Computed Tomography

Zhao, Binsheng, Colville, Jane, Kalaigian, John, Curran, Sean, Jiang, Li, Kijewski, Peter, Schwartz, Lawrence H. · 2006 · Journal of Computer Assisted Tomography
Cited by 70

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To develop a computerized method to automatically quantify visceral and subcutaneous fat distribution within the abdomen and pelvis on volumetric computed tomographic (CT) images. METHODS: Given the slices of interest, the algorithm automatically delineates a contour that separates the visceral fat from the subcutaneous fat on each slice. Explicitly, starting with extraction of the body perimeter, radii at a fixed angle increment are drawn from the perimeter to the center of the body. Along each radius, intensity profile is analyzed to determine the point on the subcutaneous fat layer that is closest to the body center (inner point). All inner points are then connected to form an inner contour, and a specific smoothing algorithm is subsequently applied to correct suboptimal results. Pixels having HU values between -190 and -30 are considered fat pixels. This procedure is repeated on each of the slices of interest. The visceral and subcutaneous fat volumes computed automatically were compared with those after the radiologist's adjustments. Ratios of volumetric visceral fat-to-total fat and visceral fat-to-subcutaneous fat were compared on average and with single-slice measurements obtained at L4 and L5 vertebral body levels. RESULTS: Subcutaneous and visceral fat were automatically segmented using this algorithm on 419 axial CT slices in 9 CT scans (patients) within the abdomen and pelvis. The overall average percentage difference between the automated segmentation and the segmentation edited by the radiologist were 1.54% for the visceral fat and 0.65% for the subcutaneous fat. CONCLUSIONS: Preliminary results have shown that total compartmental fat, including visceral and subcutaneous fat, can be automatically and accurately segmented on volumetric CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.rct.0000228164.08968.e8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 70

Metadata

Authors
Zhao, B., Colville, J., Kalaigian, J., Curran, S., Jiang, L., Kijewski, P., & Schwartz, L. H.
Venue
Journal of Computer Assisted Tomography
Published
2006-09
Volume
30
Issue
5
Pages
777-783
ISSN
0363-8715 (ISSN-L)
OpenAlex
W1992712179
Cited by
70
References
2
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Quantification of Body Fat Distribution on Volumetric Computed Tomography. https://app.cochat.ai/papers/10.1097/01.rct.0000228164.08968.e8
The paper
Zhao, B., Colville, J., Kalaigian, J., Curran, S., Jiang, L., Kijewski, P., & Schwartz, L. H. (2006). Automated Quantification of Body Fat Distribution on Volumetric Computed Tomography. Journal of Computer Assisted Tomography. https://doi.org/10.1097/01.rct.0000228164.08968.e8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.