Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,682

The DOI matches its Crossref record.

Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths

Rohrer, Martin, Bauer, Hans, Mintorovitch, Jan, Requardt, Martin, Weinmann, Hanns-Joachim·2005·Investigative Radiology

Abstract

RATIONALE AND OBJECTIVES: To characterize and compare commercially available contrast media (CM) for magnetic resonance imaging (MRI) in terms of their relaxivity at magnetic field strengths ranging from 0.47 T to 4.7 T at physiological temperatures in water and in plasma. Relaxivities also were quantified in whole blood at 1.5 T. METHODS: Relaxivities of MRI-CM were determined by nuclear magnetic resonance (NMR) spectroscopy at 0.47 T and MRI phantom measurements at 1.5 T, 3 T, and 4.7 T, respectively. Both longitudinal (T1) and transverse relaxation times (T2) were measured by appropriate spin-echo sequences. Nuclear magnetic resonance dispersion (NMRD) profiles were also determined for all agents in water and in plasma. RESULTS: Significant dependencies of relaxivities on the field strength and solvents were quantified. Protein binding leads to both increased field strength and solvent dependencies and hence to significantly altered T1 relaxivity values at higher magnetic field strengths. CONCLUSIONS: Awareness of the field strength and solvent associated with relaxivity data is crucial for the comparison and evaluation of relaxivity values. Data observed at 0.47 T can thus be misleading and should be replaced by relaxivities measured at 1.5 T and at 3 T in plasma at physiological temperature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.rli.0000184756.66360.d3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,682

Metadata

Authors
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J.
Venue
Investigative Radiology
Published
2005-11
Volume
40
Issue
11
Pages
715-724
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2030003406
Cited by
1,682
References
0
FWCI
29.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths. https://app.cochat.ai/papers/10.1097/01.rli.0000184756.66360.d3
The paper
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005). Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths. Investigative Radiology. https://doi.org/10.1097/01.rli.0000184756.66360.d3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.