Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
RATIONALE AND OBJECTIVES: To characterize and compare commercially available contrast media (CM) for magnetic resonance imaging (MRI) in terms of their relaxivity at magnetic field strengths ranging from 0.47 T to 4.7 T at physiological temperatures in water and in plasma. Relaxivities also were quantified in whole blood at 1.5 T. METHODS: Relaxivities of MRI-CM were determined by nuclear magnetic resonance (NMR) spectroscopy at 0.47 T and MRI phantom measurements at 1.5 T, 3 T, and 4.7 T, respectively. Both longitudinal (T1) and transverse relaxation times (T2) were measured by appropriate spin-echo sequences. Nuclear magnetic resonance dispersion (NMRD) profiles were also determined for all agents in water and in plasma. RESULTS: Significant dependencies of relaxivities on the field strength and solvents were quantified. Protein binding leads to both increased field strength and solvent dependencies and hence to significantly altered T1 relaxivity values at higher magnetic field strengths. CONCLUSIONS: Awareness of the field strength and solvent associated with relaxivity data is crucial for the comparison and evaluation of relaxivity values. Data observed at 0.47 T can thus be misleading and should be replaced by relaxivities measured at 1.5 T and at 3 T in plasma at physiological temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design
Lauffer, R. B. (1987) · Chemical Reviews · doi:10.1021/cr00081a003 · Cited by 1,978
Pulse and Fourier Transform NMR
(1971) · Elsevier eBooks · doi:10.1016/c2009-0-22110-6 · Cited by 1,425
Proton Relaxation Times in Paramagnetic Solutions. Effects of Electron Spin Relaxation
Bloembergen, N., & Morgan, L. O. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731684 · Cited by 1,348
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231
Self-citationProton Relaxation Times in Paramagnetic Solutions
Bloembergen, N. (1957) · The Journal of Chemical Physics · doi:10.1063/1.1743771 · Cited by 1,056
Preclinical evaluation of Gd-EOB-DTPA as a contrast agent in MR imaging of the hepatobiliary system.
Schuhmann-Giampieri, G., Schmitt-Willich, H., Press, W. R., Negishi, C., Weinmann, H. J., & Speck, U. (1992) · Radiology · doi:10.1148/radiology.183.1.1549695 · Cited by 380
Self-citationModification of human red cells by virus action; agglutination by incomplete Rh antibody.
CHU, C. M., & Coombs, R. R. A. (1947) · PubMed · Cited by 341
Studies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Tissue-specific MR contrast agents
Weinmann, H.-J., Ebert, W., Misselwitz, B., & Schmitt-Willich, H. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00332-7 · Cited by 250
Self-citationNMR relaxation of protons in tissues and other macromolecular water solutions
Fullerton, G. D., Potter, J. L., & Dornbluth, N. C. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90172-2 · Cited by 221
Gadobenate Dimeglumine (Gd-BOPTA): An Overview
KIRCHIN, M. A., PIROVANO, G. P., & SPINAZZI, A. (1998) · Investigative Radiology · doi:10.1097/00004424-199811000-00003 · Cited by 218
Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.
Hamm, B., Vogl, T. J., Branding, G., Schnell, B., Taupitz, M., Wolf, K. J., & Lissner, J. (1992) · Radiology · doi:10.1148/radiology.182.1.1309218 · Cited by 175
Transverse relaxivity of particulate MRI contrast media: From theories to experiments
Muller, R. N., Gillis, P., Moiny, F., & Roch, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220203 · Cited by 171
Taupitz, M., Wagner, S., Schnorr, J., Kravec, I., Pilgrimm, H., Bergmann-Fritsch, H., & Hamm, B. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000129472.45832.b0 · Cited by 157
Kellar, K. E., Fujii, D. K., Gunther, W. H. H., Briley-S�b�, K., Bj�rnerud, A., Spiller, M., & Koenig, S. H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200005)11:5<488::aid-jmri4>3.0.co;2-v · Cited by 138
Gadolinium-DTPA in MR imaging of glioblastomas and intracranial metastases.
Claussen, C. D., Laniado, M., Schörner, W., Niendorf, H.-P., Weinmann, H., Fiegler, W., & Felix, R. (1985) · PubMed Central · Cited by 83
Self-citationHerborn, C. U., Lauenstein, T. C., Ruehm, S. G., Bosk, S., Debatin, J. F., & Goyen, M. (2003) · Investigative Radiology · doi:10.1097/00004424-200301000-00004 · Cited by 83
Reimer, P., Müller, M., Marx, C., Wiedermann, D., Muller, R. N., Rummeny, E., Ebert, W., Shamsi, K., & Peters, P. E. (1998) · Radiology · doi:10.1148/radiology.209.3.9844683 · Cited by 67
Schnorr, J., Wagner, S., Abramjuk, C., Wojner, I., Schink, T., Kroencke, T. J., Schellenberger, E., Hamm, B., Pilgrimm, H., & Taupitz, M. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000133944.30119.cc · Cited by 54
Introduction to magnetic resonance, with applications to chemistry and chemical physics
F.H (1974) · Journal of Molecular Structure · doi:10.1016/0022-2860(74)85019-2 · Cited by 52
NEW MR IMAGING CONTRAST AGENTS
Earls, J. P., & Bluemke, D. A. (1999) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00021-0 · Cited by 30
Bjørnerud, A., Johansson, L. O. M., & Ahlström, H. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10058 · Cited by 24
IBRAHIM, M. A., Emerson, J. F., & Cotman, C. W. (1998) · Investigative Radiology · doi:10.1097/00004424-199803000-00005 · Cited by 14
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Strategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Quantum Dots and Their Multimodal Applications: A Review
Bera, D., Qian, L., Tseng, T.-K., & Holloway, P. H. (2010) · Materials · doi:10.3390/ma3042260 · Cited by 1,365
“7 T [380].”
Metadata
- Authors
- Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J.
- Venue
- Investigative Radiology
- Published
- 2005-11
- Volume
- 40
- Issue
- 11
- Pages
- 715-724
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2030003406
- Cited by
- 1,682
- References
- 24
- FWCI
- 29.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.