Multimodal Contrast Agent for Combined Computed Tomography and Magnetic Resonance Imaging Applications
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective of this study was to examine the feasibility of a multimodal system to effectively induce and maintain contrast enhancement in both computed tomography (CT) and magnetic resonance (MR) for radiation therapy applications. MATERIALS AND METHODS: The physicochemical characteristics of a liposome-encapsulated iohexol and gadoteridol formulation were assessed in terms of agent loading efficiencies, size and morphology, in vitro stability, and release kinetics. The imaging properties of the liposome formulation were assessed based on T1 and T2 relaxivity measurements and in vitro CT and MR imaging in a phantom. A preliminary imaging-based evaluation of the in vivo stability of this multimodal contrast agent was also performed in a lupine model. RESULTS: The average agent loading levels achieved were 26.5+/-3.8 mg/mL for iodine and 6.6+/- 1.5 mg/mL for gadolinium. These concentrations correspond to approximately 10% of that found in the commercially available preparations of each of these agents. However, this liposome-based formulation is expected to have a smaller volume of distribution and prolonged circulation lifetime in vivo. This multimodal system was found to have high agent retention in vitro, which translated into maintained contrast enhancement (up to 3 days) and stability in vivo. CONCLUSIONS: This study demonstrated the feasibility of engineering a multimodal contrast agent with prolonged contrast enhancement in vivo for use in CT and MR. This contrast agent may serve as a valuable tool for cardiovascular imaging as well as image registration and guidance applications in radiation therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Liu, J., Xiao, Y., & Allen, C. (2004) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10533 · Cited by 358 · cited 1×
“The in vitro release kinetic profile for both agents was assessed by the dialysis method.(22) In short, 1 mL of the liposome sample was placed in a dialysis bag (MWCO 8000) suspended in 250 mL of HBS and incubated at 4°C or 37°C.”
MethodSelf-citation
Cited by
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography
Hyafil, F., Cornily, J.-C., Feig, J. E., Gordon, R., Vucic, E., Amirbekian, V., Fisher, E. A., Fuster, V., Feldman, L. J., & Fayad, Z. A. (2007) · Nature Medicine · doi:10.1038/nm1571 · Cited by 467
Iodinated blood pool contrast media for preclinical X-ray imaging applications – A review
Hallouard, F., Anton, N., Choquet, P., Constantinesco, A., & Vandamme, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.066 · Cited by 265
Metadata
- Authors
- Zheng, J., Perkins, G., Kirilova, A., Allen, C., & Jaffray, D. A.
- Venue
- Investigative Radiology
- Published
- 2006-03
- Volume
- 41
- Issue
- 3
- Pages
- 339-348
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2005556719
- Cited by
- 95
- References
- 3
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multimodal Contrast Agent for Combined Computed Tomography and Magnetic Resonance Imaging Applications. https://app.cochat.ai/papers/10.1097/01.rli.0000186568.50265.64
- The paper
- Zheng, J., Perkins, G., Kirilova, A., Allen, C., & Jaffray, D. A. (2006). Multimodal Contrast Agent for Combined Computed Tomography and Magnetic Resonance Imaging Applications. Investigative Radiology. https://doi.org/10.1097/01.rli.0000186568.50265.64
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.